Troubleshooting
6-2
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Troubleshooting Tables
Melter not Functioning
Problem
Possible Cause
Corrective Action
No line voltage
−
Connect line voltage
Main switch not switched
on
−
Switch on main switch
Main switch defective
−
Replace main switch
Main circuit breaker
activated
−
Switch on main circuit breaker
Main circuit breaker
activated again
Check for short circuit in melter or
accessories
−
24 V
DC
power supply
defective
−
Replace
One Channel does not Heat
Problem
Possible Cause
Corrective Action
Temperature controller
does not work properly
Temperature controller defective
Replacing Temperature Controller
No Line Speed Signal
Problem
Possible Cause
Corrective Action
Parent machine not
operating
−
Start up parent machine
Polarity of line speed
voltage input is reversed
−
Reverse polarity