Maintenance
5-21
P/N 7146386A
E
2008 Nordson Corporation
VBN w/o Control System
Replacing Filter Cartridge
Nordson recommends keeping a supply of filter cartridges on hand to
prevent disruptions in production.
NOTE:
Replace only when the filter cartridge is warm and the material is
soft (approx. 70
°
C / 158
°
F, depending on material).
WARNING:
System and adhesive pressurized. Relieve system pressure.
Failure to observe can result in serious burns.
1
2
3
Fig. 5-25
1 Filling valve
2 Filter cartridge
3 Drip tray
NOTE:
Proceed as described in the section
Maintenance
−
Replacing Filter
Cartridge
to replace the filter cartridge.
Cleaning Filter Cartridge
NOTE:
Proceed as described in the section
Maintenance
−
Cleaning Filter
Cartridge
to clean the filter cartridge.