33
Analogue Output
The analogue output is designed for connection to a control system. The DAC has an update time of 1 kHz.
The calibration of the analogue output is factory set and not adjustable.
The analogue output is PIN 11.
If the output is measured against PIN 12 (2.5 V) the signal will swing positive for clockwise torque and
negative for anticlockwise torque.
If the output is measured against PIN 13 (0 V) the signal will always be positive, with zero torque around 2.5 V.
NOTE:
Some transducers (Norbar Annular type) will give a negative output change for a positive
torque. This is because they are designed to measure reaction torque.
External Snug Trigger Input
The external snug trigger is used to start the angle measurement; for external operation ensure the Target
Setup has “Internal Snug Torque Trigger” UN-TICKED. Use logic 5 V (HIGH) input with reference to pin 9 (0 V).
Connector Type
15 way female ‘D’ type connector.