background image

 
 

 
 

 

 

 

 

 

 

 

 

 

 

 

OPERATOR’S MANUAL 

T-BOX™ 2 

Part Number 34474 | Issue 3 | Original Instructions (English) 

 

NORBAR TORQUE TOOLS LTD 

Wildmere Road, Banbury, 

Oxfordshire, OX16 3JU 

UNITED KINGDOM 

Tel + 44 (0)1295 270333 

Email [email protected]  

 

 

 

NORBAR TORQUE TOOLS 

45–47 Raglan Avenue, Edwardstown, 

SA 5039 

AUSTRALIA 

Tel + 61 (0)8 8292 9777 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INC 

36400 Biltmore Place, Willoughby, 

Ohio, 44094 

USA 

Tel + 1 866 667 2279 

Email [email protected] 

 

 

 

 

 

 

 

 

 

NORBAR TORQUE TOOLS PTE LTD 

194 Pandan Loop 

#07-20 Pantech Business Hub 

SINGAPORE 128383 

Tel + 65 6841 1371 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS (SHANGHAI) LTD 

91 Building- 7F, No. 1122, Qinzhou North Road, 

Xuhui District, Shanghai 

CHINA 201103 

Tel + 86 21 6145 0368 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INDIA PVT. LTD 

Plot No A-168, Khairne Industrial Area, 

Thane Belapur Road, Mahape, 

Navi Mumbai – 400 709 

INDIA 

Tel + 91 22 2778 8480 

Email [email protected] 

 

 

www.norbar.com 

 

 

 

© Norbar Torque Tools Ltd 2020 

Содержание T-BOX 2

Страница 1: ...ce Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371 Email enquires norbar s...

Страница 2: ...arget Editor 22 Linked Targets 23 Graphing Screen 24 Axis Configurator 25 Graphing Settings Menu 26 Settings Screen 27 Units Screen 28 Serial Port 28 System Info 28 Password 28 Software Update Procedu...

Страница 3: ...his manual Parts Included Part Number Quantity T Box 2 Instrument with TDMS Software 43542 1 Power supply adapter 39979 1 USB Flash drive Operator s Manual Software 61908 1 Quick Reference Guide 34475...

Страница 4: ...y s connector and serial port Continuous Data logging of Torque or Torque Angle results Selectable frequency response for each mode of operation Ancillaries connector for each transducer with analogue...

Страница 5: ...4 Assembly and Connections Assembly of the T Box 2 onto the Stand...

Страница 6: ...5 Front Panel Connectors WARNING TO TURN ON AND OFF THE T BOX 2 USE EITHER THE POWER BUTTON ON THE FRONT PANEL OR THE POWER ICON IN THE T BOX SOFTWARE Power Switch 2 x USB...

Страница 7: ...operation they are both identical If you need to turn off your T Box 2 tap the power icon in the bottom left corner and then select Shut Down IMPORTANT TO TURN ON AND OFF THE T BOX 2 USE EITHER THE PO...

Страница 8: ...ckly change targets while taking measurements Alternatively you may wish to measure something to capture readings while graphing the output simultaneously in the other window Or you may wish to measur...

Страница 9: ...sure Screen Once selected you will be taken to the Measure Screen The example below shows a torque transducer 500 N m connected to AnB port 1 and a force transducer 50 N attached to AnB port 2 If you...

Страница 10: ...f using a target with a defined number of readings it will show X of Y readings captured against the target Reset Counter If using a target with specified reading count resets the X of Y reading count...

Страница 11: ...and to save readings to disk Delete Selected Deletes the selected reading if one is selected or the last reading taken if none are selected Delete All Deletes all readings for the current AnB port So...

Страница 12: ...r auto reset can be triggered by any drop in signal or only when the signal drops below AFL Hold Time How long it takes the Auto Reset to complete in some modes Auto Reset may be cancelled if conditio...

Страница 13: ...he current measurement mode based on the settings above Cancel Cancel mode setting any changes will not be saved NOTE Not all settings are available in all modes some are mode specific TIP If you want...

Страница 14: ...target in the chain This lets you sweep through a range of targets in a single smooth motion and capture pass fail criteria as you go NOTE Progressive Reset only works when Auto Reset is enabled NOTE...

Страница 15: ...sweep It is not necessary to set a corresponding target on the AnB module receiving the broadcast trigger in this example the torque AnB however you can do so if you want to express a pass fail condit...

Страница 16: ...h to If you change your mind and do not wish to switch just pick the units you were using before If certain units have been disabled in the Settings Units Screen then they will appear greyed out and c...

Страница 17: ...3 3 where the result is 50 67 N m the result will be green pass If the result was too low 43 74 N m the colour will be yellow and too high 53 60 N m will be red The same colouration applies to angle a...

Страница 18: ...n it To open a file double tap on it or select it and then tap the Select button TIP You may need to scroll this screen to see the full list of folders files Drive Button Breadcrumbs Folder contents E...

Страница 19: ...heet software or copy the file to a PC with spreadsheet software Readings file tbrf Opens Readings Screen and offers to load the file or combine its data with any current readings Readings file csv Ca...

Страница 20: ...rage This allows for much better organisation of targets For instance you might choose to categorise targets by which type or which capacity of tool they are for You can use the Targets file capabilit...

Страница 21: ...argets while taking measurements When opened directly from the main menu or File Browser the Targets Screen will set or clear targets on whichever AnB port is being actively used in the other window T...

Страница 22: ...ot need to ask your intentions If you disable implicit AnB selection the Targets screen will never attempt to guess which AnB module you are interested in instead asking you every time to confirm whic...

Страница 23: ...of measurement for this target Available units will change depending on target type Torque Pressure or Force Torque Only This will set a Torque only target no angle Torque Then Angle This will set a T...

Страница 24: ...gets In previous T Box generations users had to create all the targets in advance and then exhaustively specify which target would be next for each target they wanted to link In T Box 2 you simply set...

Страница 25: ...lso quite easy to use To set up a graph to suit your needs just tap one of the XY axis pair buttons at the bottom of the screen This will open the axis configurator where you can choose the X and Y ax...

Страница 26: ...e or custom value or TD min max value for TD axes Axis Colour Set the colour plotted on the graph Sample Rate Change the sample rate default 30Hz Disable Axis Shuts down axis and removes the plot line...

Страница 27: ...designated settings unless you are deliberately opening a different preset Max Graph Duration Set an upper limit on how long a graph recording can be Set to zero to disable the limit graph will stop...

Страница 28: ...ws you to configure and change various system settings Units Opens the Units Screen Serial Port Opens the Serial Port Setup Screen System Info Opens the System Info Screen Password Opens the Password...

Страница 29: ...rwise no data or corrupted data may be received TIP You will need to scroll this screen to see the full list of settings System Info Here you can see details about your T Box 2 system and perform firm...

Страница 30: ...d the wrong password they will be notified 7 When finished the UI will notify you that it is done and it needs to close Press the Finish button to close the UI 8 Re launch the new user interface to op...

Страница 31: ...pulse Angle display shown to 2 decimal places as examples Transducer Pulses per Revolution Transducer Pulses per Degree Quadrature Logic States per Degree T Box 2 Resolution 360 1 0 25 0 25 720 2 0 12...

Страница 32: ...ransducers can be factory programmed with a second degree polynomial so any slight errors can be reduced These transducers are identified as linearised on the transducer information screen Pin Connect...

Страница 33: ...r use as an EXTERNAL PRINT RESET The switch must remain active for at least 200 mS Screened cable is recommended Limit Outputs Pins 3 4 5 6 7 8 are buffered logic outputs intended for Go No Go control...

Страница 34: ...rque If the output is measured against PIN 13 0 V the signal will always be positive with zero torque around 2 5 V NOTE Some transducers Norbar Annular type will give a negative output change for a po...

Страница 35: ...cted Data Output Example Code DP Decimal Point CR Carriage Return LF Line Feed SP Space T Box 2 with the serial port set to the factory defaults Reading 1068 4 lbf ft clockwise 1 0 6 8 DP 4 SP l b f D...

Страница 36: ...e the instrument is functioning at maximum accuracy are available Do not remove the T Box 2 case there are no parts for operator repair inside Cleaning Do not use abrasives or solvent based cleaners P...

Страница 37: ...as the receiving equipment 2 Check that all serial port parameters Data bits Stop bits Parity Flow Control on the T Box 2 and the receiving equipment match 3 Check the correct null modem serial lead i...

Страница 38: ...t available tap on the currently selected target this will de select it then tap New 13 Tap SELECT UNITS and Press N m 14 Tap TORQUE ONLY you should now see the Targets New Screen 15 Tap just under TA...

Страница 39: ...on 3 Tap Main Storage 4 Tap home 5 Double tap user 6 Scroll to Readings 7 Single tap Readings Copy Results 8 Tap Copy Navigating to the Memory Stick 9 Tap the Drive Icon 10 Tap Removable Media 11 Doub...

Страница 40: ...t screen for the AnB module connected to the pressure transducer Go to Mode settings and change the mode to Hydraulic Enable Auto Reset Progressive Reset and Broadcast Capture Trigger then press Set t...

Страница 41: ...Amount of memory Lemo Reference for manufacturers of connector mA milli amp One thousandth of an amp 0 001A MB Megabyte Amount of digital memory mS Millisecond One thousandth of a second 0 001 second...

Страница 42: ...ce Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371 Email enquires norbar s...

Отзывы: