Instruction Manual
NIVUS Full Pipe
page 22
NFP - rev. 04 / 23.05.2018
Installation and Connection
19
General Installation Instructions
For electric installation the local regulations in the respective countries (in Germany e. g.
VDE 0100) must be referred to.
WARNING
Separate protection
The NFP power supply must be separately protected by a 6 A slow-blow fuse and has to be
isolated from other facility parts (separate turn-off, e. g. by using an automatic cut-out with
>B< characteristics).
Before feeding the rated voltage the transmitter and sensor installation must be correctly
completed. The installation should be carried out by qualified personnel only.
Further statutory standards, regulations and technical rulings have to be taken into account.
All outer circuits, wires and lines connected to the device must have a minimum isolation re-
sistance of 250 kOhm. If the voltage exceeds 42 V DC an isolation resistance with 500 kOhm
min. will be required.
The cross-sectional dimension of the power supply wires must be 0.75 mm
2
(0.03 in
2
) and
must be in accordance to IEC 227 or IEC 245. The device protection rating is IP65. The max-
imum allowed switching voltage on the relay contacts must not exceed 250 V. According to
Ex protection it must be checked if the devices power supplies must be integrated into the fa-
cility’s emergency shutdown conception.
20
Transmitter Installation and Connection
Important hints on installation
Ensure proper installation.
Follow applicable legal or operational guidelines.
Improper handling may lead to personal injuries and/or equipment damage.
20.1 General
The transmitters mounting place has to be selected according to certain criteria.
Please strictly avoid:
•
direct sunlight (use weatherproof cover if necessary)
•
heat emitting objects (max. ambient temperature see chapter “15 Specifications”)
•
objects with strong electromagnetic fields (e. g. frequency converters or similar)
•
corrosive chemicals or gas
•
mechanical shocks
•
installation close to footpaths or travel ways
•
vibrations
Содержание NFP
Страница 82: ...Instruction Manual NIVUS Full Pipe page 82 NFP rev 04 23 05 2018 Approvals and certificates...
Страница 83: ...Approvals and certificates NFP rev 04 23 05 2018 page 83...
Страница 84: ...Instruction Manual NIVUS Full Pipe page 84 NFP rev 04 23 05 2018...
Страница 85: ...Approvals and certificates NFP rev 04 23 05 2018 page 85...
Страница 86: ...Instruction Manual NIVUS Full Pipe page 86 NFP rev 04 23 05 2018...
Страница 87: ...Approvals and certificates NFP rev 04 23 05 2018 page 87...