Electrical System - Battery Version
41
Service Manual – SC450
Charge condition display
INDICATION
TRANSITION THRESHOLD (VOLT)
CONSEQUENCE
WET
GEL
1
GREEN LED: fixed - YELLOW LED: fixed
22 V
22.2 V
-
2
YELLOW LED: fixed - RED LED: flashing
20.4 V
21.6 V
B Vacuum system
OFF
Troubleshooting
Trouble
Possible Causes
Remedy
The machine is not working
The batteries (BAT) are discharged or its connections are
not efficient
Charge the batteries or clean/repair
the connections
The batteries (BAT) are broken
Check the battery no-load voltage
The battery charger (CH) is broken
Replace
The fuses (F1, F2, F3) are open
Replace
The wiring harness is cut or pressed or short circuited
Repair