Scrub System, Disc - Battery Version
66
Service Manual – SC450
Troubleshooting
Open Circuit
•
The brush fuse (F1) determines an open in the supply circuit of the brush deck motor This system allows
to prevent the circuits from being damaged under overload conditions
•
The open in the fuse can be caused by the following:
•
Short circuit in the brush motor wiring harness; fault in the motor
Trouble
Possible Causes
Remedy
The brush does not clean properly
The brush is excessively worn
Replace
One brush does not turn
Activation of motor overload
Restart the machine
The motor carbon brushes are worn
Replace
The motor is faulty
Check the motor amperage/replace
There are ropes or debris restraining the brush rotation
Remove and clean
The brush fuse (F1) is open
Replace
The motor electromagnetic switch (ES1) is damaged
Replace
The brush motor electromagnetic switch wiring harness
is damaged
Repair
The brush motor electromagnetic switch wiring harness
is damaged
Repair
The wiring harness between function electronic board
(EB1) and brush motor electromagnetic switch (ES1) is
damaged
Repair