Electrical System - Battery Version
37
Service Manual – SC450
Battery Charging
Note:
Charge the batteries when the yellow or red warning light on the control panel turns on,
or at the end of every working cycle.
Caution! Keeping the batteries charged make their life last longer.
Caution! When the batteries are discharged, charge them as soon as possible, as that
condition makes their life shorter. Check for battery charge at least once a week.
Caution! If the machine is not equipped with on-board battery charger, choose an external
battery charger suitable for the type of batteries installed.
Caution! WET battery charging produces highly explosive hydrogen gas. Charge the batteries
in well-ventilated areas and away from naked flames. Do not smoke while charging
the batteries.
Do not reinstall the recovery tank until the battery charging cycle is over.
Caution! Pay careful attention when charging WET batteries as there may be battery fluid
leakages. The battery fluid is corrosive. If it comes in contact with skin or eyes, rinse
thoroughly with water and consult a physician.
Caution! It indicates a caution related to important or useful functions.
1 Drive the machine to the appointed recharging area
2 Turn off the machine by turning the switches to “0”
3 For WET batteries only:
– Tip up the recovery tank
–
Check the level of electrolyte inside the batteries; if necessary, top up through the caps.
– Leave all the battery caps open for next charging
–
If necessary, clean the upper surface of the batteries.
4. Charge the batteries according to one of the following procedures, depending on the presence of the
electronic battery charger