Solution System - Battery Version
82
Service Manual – SC450
Solution System - Battery Version
Functional Description
The solution system supplies the detergent to the
brushes when cleaning the floor. The solution tank is
also the main machine body The detergent quantity
is adjusted by the operator with the lever under the
solution tank, on the left rear side. The solution flows
from the tank to the tap, through the filter and sole
-
noid valve (EV1) and then to the brush deck
The solenoid valve (EV1) is supplied by the function
electronic board (EB1) when the switches (SW1) and
(SW3 with SW4) are closed The circuit is protected
by the control/solenoid fuse (F3) on the function elec
-
tronic board (EB1). The solution flow is regulated by
the manual solution flow control lever.
Wiring Diagram
FUNCTION ELECTRONIC
BOARD (EB1)
SOLENOID VALVE
(EV1)
SOLENOID VALVE AND
ELECTRONIC BOARD FUSE (F3)
BRUSH
SWITCH (SW1)
BRUSH ACTIVATION
PUSH-BUTTONS (SW3) (SW4)
J2.6 - Power supply (-)
J2.7 - Power supply (+)
J3.1 - Solenoid valve (+)
J3.2 - Solenoid valve (-)
J1.1 - Switch power supply
J1.8 - Brush system switch
J1.2 - Brush switch
24V
24V
B -
P200033