Electrical System - Battery Version
40
Service Manual – SC450
Fuse Check and Replacement
1. Drive the machine on a level floor. Make sure that the machine cannot move independently.
2 Check that the control panel switches are turned to “0” Disconnect the battery connector (red)
3 Move aside the recovery water drain hose
4. Remove the battery charger cable, if equipped, from the cable holder.
5 Remove the screws (A)
6 Carefully move the panel (B) by disengaging the wiring harness grommet (C) from its housing
7 Check the following fuses for integrity:
– (D) Brush deck fuse F1 (40 A)
– (E) Vacuum system fuse F2 (30 A)
– (F) Electronic board fuse F3 (5 A)
8. Replace the open fuse, when the component that caused deactivation has fully cooled down.
9. Engage the grommet (C) and install the cover (B), then tighten the screws.
10. Place the battery charger cable, if equipped, on the cable holder.
11 Connect the battery connector (red)
D
E
F
A
A
B
A
C
P2000015