Recovery System - Cable Version
57
Service Manual – SC450
Troubleshooting
Trouble
Possible Causes
Remedy
The vacuum system motor does not turn
on
The vacuum system motor carbon brushes are worn
Replace
The switch (SW2) is broken
Replace
The vacuum system motor is faulty
Check the amperage.
Check the carbon brushes.
Replace.
The recovery water vacuuming is
insufficient or there is no vacuuming
The vacuum grid with automatic shut-off float is activated
because the recovery tank is full
Drain the recovery tank
The vacuum grid is dirty
Clean
The tank cover is not correctly positioned
Adjust
The tank cover gasket is not efficient
Clean/replace
The vacuum system motor filter is dirty
Clean
The vacuum gaskets are damaged or do not match
perfectly
Repair or replace
The squeegee vacuum hose is broken
Replace
The recovery tank vacuum hose is broken
Replace