3
REC/
EN
T
2. Outputting Data to the COM Port
Press the [ENT] key while the
icon is shown
on observation screens, a line of data is output
through COM port.
When
is displayed, data will NOT be
stored to the Job by [ENT].
[ENT]
Format of the output data is defined by
“Ext.Comm=NIKON or SET” in [MENU]
→
[3.Settings]
→
[5.Comm]. (See p.3-99)
•
To output data upon pressing [ENT], “Data Rec”
setting in [MENU]
→
[3.Settings]
→
[8.Rec] should
be set to “COM”. (See p.3-101)
= Sample output records through COM port =
<Ext.Comm=NIKON>
TR PN: PT8 SD:000066626 HA:003856010 VA:008048500 HT:0000061757
(TR PN: point name SD HA VA HT; when ACK is returned, PN is incremented.)
<Ext.Comm=SET>
0006662 0804806 0394324 97
(SD VA HA Chk-SUM)