Caution

Safety Precaution

Caution

Caution before use.

•Location which will be gotten water

•Locations which receive direct sunlight

•Dew condensation place

Do not use AC plug covered with dust.

Do not use and keep FGV under the 
following circumstances.

Please use the FGV in operating
temperature in range 32 - 104°F 
(0 - 40°C).

A potential fire hazard may exist

To clean the FGV do not use a volatile chemical 
such as benzene, thinner or alcohol.  Only use a 
dry soft cloth or a cloth soaked in a mild detergent 
that is mixed with water.  

If you use FGV beyond above temperature, 
FGV might operate unusual.

1. Do not press the button with 

a sharp-pointed object.

2. Do not load in an axial direction

PEAK

ZERO

MEM

UNIT

PEAK

ZERO

MEM

UNIT

PEAK

ZERO

MEM

UNIT

The FGV can measure pulling and compression loads, but not loads 
in a rotational direction.  The FGV is equipped with a limit stopper.  
However, this is unable to prevent damage from a heavy impact load 
or excessive axial forces.

Bending direction

Twisting direction

Accuracy performance degrades overtime.  It 
is recommended the force gauge be checked 
for performance regularly.  The frequency of the 
checks is dependent on the frequency of use and 
loading.

3. Do not drop the force gauge.

Do not allow the force 
gauge to fall. The sensor 
can become damaged 
and will no longer be 
able to perform properly.

PEAK

ZERO

MEM

UNIT

4. Do not use the force gauge in locations where it may get wet.

This force gauge is not water 
proof.  Please do not operate 
the force gauge in locations 
where it may get wet.

PEAK

ZERO

MEM

UNIT

5. Measuring very small loads

Factory default, the tracking setting 
is set to ON.  When measuring small 
loads, turn the tracking setting to 
OFF. Refer to Tracking Section for 
further details.

PEAK

ZERO

MEM

UNIT

Please operate the force gauge 
within operating humidity range; 
35-85% RH.

If you use the force gauge beyond the above 
range, it might produce improper operation.

•Dusty, salinity and iron content environments

•Location which will be gotten oil and chemical

•Corrosive and Flammable gas environment

Overload

Содержание FGV-HXY

Страница 1: ...e to the sensor may occur Do not modify disassemble or attempt to repair the unit Send to the factory for proper repair If upon delivery damage to the unit is detected do not operate the unit Notify t...

Страница 2: ...ng Caution Warning Caution Safety Precaution Serious injury or possibly even death may result if the gauge is used wrongly A serious problem or issue may result if the gauge is used wrongly Take preca...

Страница 3: ...ct load or excessive axial forces Bending direction Twisting direction Accuracy performance degrades overtime It is recommended the force gauge be checked for performance regularly The frequency of th...

Страница 4: ...7 6 6 2 Storing data 18 6 6 2 1 Continuous memory mode 18 6 6 2 2 Single memory mode 18 6 6 2 3 Standard memory mode 18 6 7 Recalling memory data 19 6 7 1 Continuous memory mode 19 6 7 1 1 Measuring m...

Страница 5: ...ith USB 6 9 USB communication 1000 data point memory 6 6 Memory Comparator shows pass or fail I O output of the result 6 5 Comparator Reverse the display of the measuring value and the unit 4 6 Revers...

Страница 6: ...ng 7 POWER key Press the POWER and release to turn ON OFF It is used to reverse the display Tracking ON OFF It is used for comparator memory setting 8 MEM key Press the MEM key under the standard meas...

Страница 7: ...of battery BAT is shown Even if turn the power off during the charge BAT will be displayed PEAK turns on when plus peak hold mode PEAK turns on when m i n u s p e a k h o l d mode Newton Depend on the...

Страница 8: ...ours per 1 full charge 2 The nickel hydride battery is charged automatically when it is discharged during the usage of AC adapter If you charge the battery frequently its lifetime will be shortened Wh...

Страница 9: ...Standard measuring mode Please release the PEAK key and UNIT key after the value appears in the display more than 1 second Tracking ON Tracking OFF Tracking OFF Tracking ON Turn power off then press...

Страница 10: ...s 0001 Display update time f02 1 2 3 5 10 20 times second 3 Auto power off f03 10 10 minutes oFF not valid 10 RS 232C baud rate f04 2400 4800 9600 19200 bps 2400 Response Time f05 3 20 150 msec 3 Exte...

Страница 11: ...easuring mode PEAK Save the change and then move to f04 5 3 Auto power off f03 If the gauge is on and there is no activity for 10 minutes the unit automatically powers off to conserve battery charge W...

Страница 12: ...e 150msec Filter response time show 90 of step input Depend on the filter response sampling period and analog output update period is decided Input change of actual load Measuring value 90 response ti...

Страница 13: ...key and UNIT key after the value appears in the display more than 1 second ZERO POWER Function mode Turn POWER off Press ZERO key and hold then press POWER key and release release ZERO key after the v...

Страница 14: ...nder the plus peak hold mode or minus peak hold mode The plus peak value or minus peak value is cleared In plus peak hold or minus peak hold modes the tare cannot be performed even when pressing and r...

Страница 15: ...ry mode setting MEM Set the memory mode single mode continuous mode standard mode Std When you set 0 at both HI limit and LOW limit comparater function does not work 6 5 3 Setting HI limit 1 Press the...

Страница 16: ...n output signal of comparator LO limit 6 6 Memory There are 3 modes at memory mode as follows Continuous memory Allows the recording of up to 1000 data points The recording starts when you push MEM an...

Страница 17: ...N MIN Continuous memory mode Ex1 Ex2 Ex3 MAX MAX MIN 0 MIN 0 MAX MAX MAX MIN Start memory Start memory Start memory Finish memory Finish memory Finish memory 0 0 0 MIN 0 MAX 0 Average value AVE Averag...

Страница 18: ...it 0 Comparator LO limit setting LO Set comparator LO limit 0 Memory mode setting MEM Set memory mode Single mode Continuous mode Standard mode Std When you set 0 at both HI limit and LO limit compara...

Страница 19: ...umber arrives at 1000 6 6 2 2 Single memory mode 1 During the standard measuring mode press MEM key M turns on at the unit display and one data is recorded 2 If 100 data points are recorded FULL appea...

Страница 20: ...orded measurement value of that block 2 Press MEM to review the previous data block recorded 3 Press UNIT to cycle through the available recorded statistics In Continuous mode the available statistics...

Страница 21: ...egative maximum value positive minimum value negative minimum value positive peak value negative peak value average value standard deviation 3 Press MEM to exit to the recorded measurement values 4 Pr...

Страница 22: ...s and release POWER Release MEM when you see Slg on the display The unit will alternate between showing the data block number and the recorded measurement value of that block 2 Press MEM to review the...

Страница 23: ...ing RS232C communication Key operation Display Turn power off PEAK ZERO MEM UNIT 1 Hold down MEM key 2 Press POWER key PEAK ZERO MEM UNIT Release POWER key only MEM Return to memory data display PEAK...

Страница 24: ...a greater detail in the next section 4 Press PEAK to output the recorded memory via RS 232C Refer to section 7 regarding RS232C communications Key operation Display Turn power off PEAK ZERO MEM UNIT...

Страница 25: ...itive minimum value negative minimum value positive peak value and negative peak value 3 Press MEM to exit to the recorded measurement values 4 Press PEAK key to output the recorded memory via RS 232C...

Страница 26: ...USB 6 9 2 Download ToriemonUSB If you connect the force gauge to a PC with the USB cable you can download data to the PC from the force gauge of the current values being measured or from data that is...

Страница 27: ...put can be set by external output setting f06 of function mode 7 2 RS 232C Output You can operate this equipment from your PC if connecting it by using optional cable for RS 232C Cannot use USB commun...

Страница 28: ...t and 4 digit number BBcr Request for continuous transmission of measuring data 10 times second BBcr NAoooooocr BB1cr Request for continuous transmission of measuring data 20 times second BB1cr NAoooo...

Страница 29: ...rnal output setting f06 function mode Maximum allowance voltage DC 30V current 5mA Please connect the power and load to avoid going over maximum allowance Overload output When the overload condition i...

Страница 30: ...limit output 8 ZERO signal input Input signal 9 HOLD signal input 10 PEAK signal input 11 Common for comparator output 12 GND The device printer provided for Mitutoyo Digimatic Please purchase the opt...

Страница 31: ...gnal input 9pin ZERO signal input 10pin GND 12pin Signal is ON DC 3 3V 0 5mA 2 HOLD signal input HOLD signal is ON when HOLD signal input pin 9 pin and GND 12 pin is changed from OPEN to CLOSE The dis...

Страница 32: ...it Questions Explanation Reference How long does rechargeable battery Nickel hydride battery last Enable to use 500 times or more by complete electric discharge It depends on the status of use Please...

Страница 33: ...CHECKED UNITS SCALE TITLE Toshi MO YS mm 1 1 MODEL ORIGINAL DRAWING NO DRAWING NO BGBM068 FGC H FGV H FGN H FGE H High Load Force Gauge Attachment Drawing M10 EJ350280 DATE 04 24 2017 Itasca IL 60143...

Страница 34: ...33...

Отзывы: