3.2 - Installation of the control unit box
Important! – Before installing the control unit box check the electrical connections in Fig. 5 and Table 3.
Danger from light emissions! – Looking at LED lights from close up and for prolonged periods can cause dazzling. It may tem-
porarily reduce eyesight and cause accidents. Avoid looking at LEDs directly.
Table 3 - Types of electrical cable (see fig. 5)
Clamp
Type of cable
Maximum
length
Function
1
MOTOR (a)
2 x 17 AWG (included)
(2 x 1 mm
2
)
16ft 4” 55/64
(5 m)
24 V DC power to the guide
2
BLUEBUS
2 x 18 AWG
(2 x 0.75 mm
2
)
65ft 7” 13/32
(20 m)
Input for Bluebus devices.
Warning
- Connect devices in parallel
3
INP 1
(SbS)
2 x 20 AWG
(2 x 0.5 mm
2
)
65ft 7” 13/32
(20 m)
Reconfigurable input 24VDC. It is factory-configured as a NO
input with SbS operation and with the motor stationary for
the unlocking of the control unit (in case of intervention of the
alarm system)
INP 1
(Light)
2 x 20 AWG
(2 x 0.5 mm
2
)
65ft 7” 13/32
(20 m)
Reconfigurable input 24VDC. It is factory-configured as: - a
NO input with Courtesy Light ON/OFF operation (SPYBOX B
/V1)
4
STOP
2 x 20 AWG
(2 x 0.5 mm
2
)
65ft 7” 13/32
(20 m)
Input for the connection of a STOP button or sensitive edge of
the 8K2 resistive type. The input is with self-recognition with
possibility NO, 8K2, NC *
5
POWER
120 VAC 50/60Hz
3 x 17 AWG (not supplied)
(3 x 1 mm
2
)
-
Control unit power
* If you use a category B resistive sensitive edge (according to EN13849-1,-2) to limit the force of impact (according to CAT 2 and Performance
Level C) you need to activate parameter L5 (level one programming) and perform search of devices
01.
1 - open the cover: loosen the screw and pull downwards until you hear a click
2 - prepare the routing for electric cables through the slot or cable glands
- Slot: you must break the knock-outs with a screwdriver
- Cable glands: it is necessary to make a hole with a drill and fasten the cable glands
1
2
3
Clik
02.
1 - install the bracket to the wall with special screws and wall plugs (not included:
∅
4 mm), where the control unit box needs to be fixed
2 -attach the box to the bracket
4 mm
Ø
*
*
1
2
Ø 5/32”