English –
17
5.6.1 - 1st level Parameters
Table 4 – 1st level Parameters
LED
Function
Description
L1
Automatic Closing
Run the automatic closing of the garage door when it is open, after the programmed pause
time has elapsed
L2
Close After Photo
Run the closing of the garage door only after transit has been completed.
Caution!
- You need to have performed the installation of the photocells
L3
Always Close
After switching on the control unit, a closing manoeuvre starts preceded by 3 sec. of pre-
flashing
L4
Stand by
This function reduces power consumption: after 1 minute from the end of the manoeuvre,
the control unit turns off the output and the BlueBUS photocell transmitters.
For use with the Solemyo system you must enable the “Stand by - all” mode using the
Oview programmer
L5
STOP 8K2
Run a test of the 8K2 sensitive edge at the start of each manoeuvre.
Activate the function then acquire the devices with the 8K2 edge connected.
L6
Lock OPEN and CLOSE buttons
Deactivates the operation of the OPEN and CLOSE buttons on the lid of the box, when the
switch is in 0 position
L7
Long / Short slowdown
If enabled, it allows for doubling the space from which the slowdown starts, during both the
opening and closing manoeuvres
L8
Pre-flashing
Activates pre-flashing before the closing manoeuvres
Programming procedure 1
st
level
01.
02.
03.
04.
05.
I
O
I
O
(SET) 3 s
L1
=
(SET)
to select the desired
function (LED: L1 ...
L8) use the OPEN or
CLOSE button
(SET)
to change the
status of the
function
= OFF
= ON
06.
10 s = exit from progr. or
I
O
I
O
5.6.2 - Level 2 parameters (ADJUSTABLE PARAMETERS)
Table 5 – 2
nd
level Parameters
Input LED
Parameter
Level
Value
Note:
the parameters with a grey background are factory settings
L1
10s
L2
20s
L3
40s
L1
Pause Time
L4
60s
L5
80s
L6
120s
L7
160s
L8
200s
L1
SbS: open - stop - close - stop
L2
SbS: open - stop - close - stop
L3
SbS: open - close - open - close
L2
Operating modes
L4
Apartment block
L5
Hold-to-run
L6
Industrial mode
L7
-
L8
-