24
– English
6.9 - Safety device for pedestrian door
The electrical board on the motor has a terminal for connecting a safety device for the pedestrian gate (microswitch Normally Closed - NC) that
stops the motor if the pedestrian door remains open.
IMPORTANT! - Only use contacts with tripping current of at least 10 A.
The connecting cable must be:
Length = 9ft 10in 1/8 (3 m) maximum
Section = 17 AWG (1 mm
2
) minimum
(diameter of cable route hole on the motor carriage is 1/4 “ - 6.5 mm)
For the connection, follow the instructions below.
01.
a - connect the safety device (refer to your instruction manual)
b - remove the cover of the motor carriage
c - remove the protective sheath of the hole on the motor carriage used for passing the cable
d - pull the cable through the hole and position it near the edge of the carriage up to the terminal (1-2)
e - remove the jumper on the terminal
f - connect the two wires to the terminal
1
2
3
b
a
e
f
c
d
CAUTION! - Fasten the cable to
prevent it from being pinched by the
garage door during manoeuvres.