English –
23
6.7 - Back-up battery model PS324 (SPYBOX B/V1)
In the event of mains power failure, SPYBOX B/V1 is designed to be powered by model PS324 backup battery. To perform the installation and
connection of the battery, proceed as follows:
CAUTION! - The backup battery should only be connected to the control unit after completing all phases of installation and pro-
gramming, because the battery is an emergency power supply.
01.
1 - cut off the mains power supply
2 - place the battery in a suitable position
3 - on the control unit box and prepare the route of the battery power cable
4 - connect to the mains power supply
5 - connect the cable to the control unit as indicated in Figure
Clik
2
1
3
5
4
ON
6.8 - Solemyo System (only for SPYBOX B/V1)
SPYBOX B/V1 is designed to be powered with the ‘Solemyo’ photovoltaic power system. For connection to the control unit, you must use the
socket of the backup battery.
IMPORTANT! - When SPYBOX B/V1 is powered by the “Solemyo” system IT MUST NOT BE POWERED from the electricity mains
at the same time.
SPY will perform a maximum number of operations per day depending on the amount of solar energy available at the installation location and
the time of year.
Note – Before installing, it is important to check in the Solemyo instruction manual whether the maximum number of possible manoeuvres is
compatible with its intended use.
Warning – In order to have effective performance from ‘Solemyo’ the ‘Stand-by - All’ function on the control unit needs to be ON: this function
can only be activated using the Oview programmer.