background image

CBOX936

INSTALLATION AND PROGRAMMING MANUAL

18

  

 

 

CONNECT BLUEBUS PHOTO EYES TO BOARD

IMAGE 6-1: 

BLUEBUS CONNECTOR LOCATION

 

If the kit comes with BlueBUS photo eye pair, connect bus wires (no polarity) into 2-pin BlueBUS connector on 
control board (IMAGE 6-1). If an alternative reflective photo eye and reflector are provided, follow installation 

instructions included in the kit.

6

1. Place one warning sign (IMAGE 7-1) on outside of gate and the other

inside of gate in high visibility locations (eye height) to warn of entrapment
dangers. If signs cannot be attached to gate, ensure they are as visible as
possible to pedestrians and anyone operating the gate.

2.

Use two tie wraps per sign, or alternative means, to securely affix signs to

gate.

7

ATTACH WARNING SIGNS TO GATE

IMAGE 7-1:

 

MOVING GATE ENTRAPMENT WARNING SIGN

BLUEBUS

CONNECTOR

IMPORTANT!

Do not attempt to jumper 

or short the BlueBus 

connector pins as this 

will damage the control 

board. 

www.ApolloGateOpeners.com  |  (800) 878-7829  |  [email protected]

Содержание HySecurity CBOX936

Страница 1: ...Installation and Programming Manual CBOX with 936 control board CBOX936 Vehicular gate operator control box with 936 control board www ApolloGateOpeners com 800 878 7829 Sales ApolloGateOpeners com...

Страница 2: ...REMOTE CONTROL 30 INSTRUCTION 20 DELETING ALL REMOTE CONTROLS 30 INSTRUCTION 21 CONTROL BOARD MENU NAVIGATION 32 INSTRUCTION 22 CALCULATE SOLAR REQUIREMENTS 44 CONTENTS LIST OF INSTRUCTIONS 2 SECTION...

Страница 3: ...System with 912L Actuator EXTREMELY IMPORTANT Anyone who installs assists with installation or otherwise facilitates the installation in any manner should thoroughly read and understand this manual i...

Страница 4: ...trol Board ENCLOSURE CBOX Type 3R 18wX18hX8d 46wX46hX20 3 ACCESSORY CONNECTORS 2x Step by Step Inputs 2x Edge Sensor Shadow Safety Free Exit Emergency Bypass RELAYS Two programmable relays UL 325 CERT...

Страница 5: ...ry as part of the kit CLASS IV RESTRICTED ACCESS GATE OPERATOR CLASS I RESIDENTIAL GATE OPERATOR CLASS II COMMERCIAL GENERAL ACCESS GATE OPERATOR CLASS III INDUSTRIAL LIMITED ACCESS GATE OPERATOR Inte...

Страница 6: ...ed that define different types of installations where gate operators can be applied Some operators are restricted in their usage application All Nice USA operators are approved for use in all four UL3...

Страница 7: ...ists such as the perimeter reachable by a moving gate or barrier CONTACT SENSORS EDGE For a gate operator utilizing a contact sensor Edge One or more contact sensors shall be located where entrapment...

Страница 8: ...pgraded to conform to the provisions of this specification in effect at that time VEHICULAR HORIZONTAL SLIDE GATE REQUIREMENTS Class I II and III Vehicular Horizontal Slide Gates The following provisi...

Страница 9: ...nding The gate should travel smoothly and quietly throughout its range If it does not contact a gate professional to correct the problem SAFETY DEVICE TESTING Reconnect gate operator and perform the f...

Страница 10: ...ly or in combination with each other to provide external entrapment protection Care should be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate i...

Страница 11: ...fore a new installation or making any modifications to an existing installation of this gate operator All wiring connections must be made by a qualified individual Run individual circuits in separate...

Страница 12: ...g gate systems are NOT intended for installation on an incline These instructions assume actuator s has been installed per the applicable actuator installation manual Install actuator before performin...

Страница 13: ...actuator for dual gate systems same side as MASTER actuator with shorter harness and at least six feet away from the pivot arm FIGURE 1 1 2 Set battery inside of control box with terminals toward the...

Страница 14: ...For dual gate systems DO NOT connect the MOTOR 2 connector to the control board yet MOTOR 2 connector will be connected at a later step NOTES If for a dual gate system prepare both actuator harnesses...

Страница 15: ...NT ZONES AND PHOTO EYE LOCATIONS NOTE Name designations in IMAGE 3 1 P1 P2 etc are arbitrary designations used to indicate jumper settings for each photo eye location See INSTRUCTION 4 for jumper sett...

Страница 16: ...b from wire entry hole E knock out rear tab for running wire underneath the mounting surface OR knock out bottom tab for running wires out the bottom 3 If more than one pair of photo eyes configure ju...

Страница 17: ...affix both to selected locations with included screws I 2 Thread 2 wire bus wire through bracket hole and snap photo eye assembly J into bracket 3 Install bus wires into screw terminals J red circle...

Страница 18: ...AGE 7 1 on outside of gate and the other inside of gate in high visibility locations eye height to warn of entrapment dangers If signs cannot be attached to gate ensure they are as visible as possible...

Страница 19: ...cable from kit strip bare wires back 3 8 7 16 10 11mm twist and install into the Battery connector screw terminals RED BLACK 3 Attach the battery cable lugs to the battery terminals black to negative...

Страница 20: ...o face north 3 Cut off two battery lugs from the end of the solar panel cable 4 Strip wires back 1 4 5 16 7 8mm twist and install into the solar panel connector screw terminals on the control board RE...

Страница 21: ...wire of solar panel to either of the regulator s black wires see IMAGE 9B 1 5 Connect the red positive battery wire see notes above to the red wire of the battery regulator and the black battery wire...

Страница 22: ...1 remove power from the board unplug battery connector then after a few seconds reapply power plug in battery connector 6 Once safety devices such as photo eyes are found and determined to be function...

Страница 23: ...wn and stop when buttons are released 4 Press and hold down each button and ensure that the CLOSE LED lights up red when gate reaches the close limit and the OPEN LED lights red up once the gate reach...

Страница 24: ...ndby Mode puts the board into a low power consumption mode after about 2 minutes of inactivity in the unlearned state and after about 20 seconds after the board has learned the current system A press...

Страница 25: ...The RX is receiving a weak signal Fair operation the photocell glass should be cleaned or re aligned Very fast flashing RX The RX is receiving a poor signal Barely operational clean the photocell glas...

Страница 26: ...Phillips screwdriver to loosen screw A 3 Place screwdriver in hole B and lever the entire assembly in desired direction to change the angle of the entire assembly by up to 15 degrees in all direction...

Страница 27: ...Pass cylinder through line of sight halfway between transmitter and receiver 4 Each time the line of sight between transmitter and receiver is obstructed the gate motion should immediately stop then r...

Страница 28: ...The audio alarm siren included in the kit must be connected to the 936 control board to provide an audible alarm to indicate a hard shutdown of the system which is triggered by two consecutive entrapm...

Страница 29: ...rol the receiver 3 After the LED on the Nice receiver blinks green 3 times another 10 second interval is started to program another Nice remote control if desired 4 Repeat step 3 to program the additi...

Страница 30: ...gate 20 DELETING ALL REMOTE CONTROLS All programmed remote controls may be removed from the Nice OXI A receiver memory as follows 1 Press and hold the button on the side of the Nice OXI A receiver mod...

Страница 31: ...Jumper Learn Input 12V a Options AutoClose SlowDown Force Close Stop 12V c 3A b c Bypass 15A Fuse A A B A B A B A B B Close Close Open Open Open COM COM Battery Solar 3A c b Open Button OK Button Up...

Страница 32: ...ters values for displayed option 4 Press UP and DOWN buttons to scroll through parameter values 5 Press OK to select parameter value shown in display TABLE 21 1 936 CONTROL BOARD BUTTON FUNCTIONS BUTT...

Страница 33: ...E BUTTON This option selects the amount of force needed to cause the gate to stop and retract when hitting an obstacle Current sensitivity should be set to a level strong enough for operation under no...

Страница 34: ...n in turn 3 Press OK while an option is displayed to enter the parameter values for that option 4 Press the UP and DOWN buttons to scroll through the parameter values 5 Press OK to accept the displaye...

Страница 35: ...2 button lock gate open STANDBY MODE Standby Mode allows board to go into a standby low power mode after 20 seconds of board inactivity Values are as follows 0 Standby Mode OFF 1 Standby Mode ON Defau...

Страница 36: ...e operator will stop and reverse to full open 2 Pulse Entrapment if the photo eye is obstructed in the open or close direction the operator will stop and reverse direction of travel for 2 seconds NOTE...

Страница 37: ...detected and functioning FLASHING Hard shutdown is active and the audible alarm sounds Display may be cleared by pressing Reset Button after obstruction is cleared from gate path FLASHING BlueBUS sca...

Страница 38: ...Jumper OXI A Plugin Receiver Oview RJ45 T4 Conn 24VDC 0 3A Out External Antenna for Plugin Receiver Signal Signal Shield 12 24 VDC BATT SOLAR PANEL BlueBUS MOTOR OUTPUT BYPASS Power Power Inputs Input...

Страница 39: ...xternally fused 12VDC power and remain powered when board is in Standby Mode Each terminal includes a pin for step by step input 12VDC 150mA POWER OUTPUT This terminal provides internally fused 150 mA...

Страница 40: ...s input pin is a Normally Open NO dry contact input that stops a moving gate momentarily reverses the gate direction then stops the gate Typically used for edge sensors SAFETY LOOP INPUT This input pi...

Страница 41: ...TPUT Dry contact relay output SPDT with Normally Open NO Normally Closed NC and common connections Active during close cycle and close limit activation ALARM OUTPUT Internally fused 0 5A output to pow...

Страница 42: ...n For manual fail safe gate operation turn power to the operator OFF If a backup power system is in use be sure that this power is turned OFF also or is disconnected Once power is OFF the gate can be...

Страница 43: ...ng and diagnostic tool which plugs directly into the 936 control board using an RJ45 network cable and is part of the Nice Opera control system The Oview controller can be used in stand alone mode via...

Страница 44: ...the amount of sunlight available per the Solar Map right 3 Use the solar wattage calculator found on the HySecurity website at https www hysecurity com operators accessories solar to determine batter...

Страница 45: ...T Check emergency vehicle access device for proper operation x x GATE Inspect for damage x LOOP S Check vehicular reverse and shadow loops for proper operation x x RELEASE Check manual release for pro...

Страница 46: ...hold the gate open and indicates a problem with the loop detector or ground loop Battery backup system will not open gate upon AC power outage Check if backup system is set to open gate automatically...

Страница 47: ...e installer has properly adjusted the obstruction sensing feature and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 4...

Страница 48: ...LLATION AND PROGRAMMING MANUAL 48 SECTION 12 PART DRAWINGS 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32 www ApolloGateOpeners com 800 878 7829 Sales ApolloGat...

Страница 49: ...1 21 KBOX1050 KIT KBOX 1050 1 21 KBOX936 KIT KBOX 936 1 22 MX3526 CLAMP CABLE 187 NYLON 1 B 7 18 2018 CJE CBOX CONTROL BOX SWING GATE CHANGE DESCRIPTION REV PART NO DESCRIPTION NAME DATE ENG APPR CHEC...

Страница 50: ...proprietary and trade secret information of Hy Security Gate Inc Hy Security Any party receiving accepting or retaining this document thereby agrees to use the document and any information contained...

Страница 51: ...s carry the name plate of a manufacturer other than HySecurity or Nice and they are not a part of the base model HySecurity disclaims all warranties for such accessory components which carry only the...

Страница 52: ...rtis Harvey Rev A Release for publication 11 13 2019 INSTALLATION INFORMATION AND SIGN OFFS Installation Acceptance Address where opener is located Installer name number and address End user name and...

Отзывы: