CBOX936
INSTALLATION AND PROGRAMMING MANUAL
14
2
WIRE ACTUATOR(S) TO CONTROL BOARD
1. Strip actuator wires back 1/4”-5/16” (7-
8mm) and twist.
2. Remove 5-pin and 2-pin connector from the
MOTOR 1 section on control board. If a dual
gate system, also remove both MOTOR 2
connectors. See IMAGE 2-1.
3. Refer to wire diagram in appropriate
actuator install manual, then use a small flat
blade screwdriver to affix wires into screw
terminals of connectors per wire diagram.
4. Plug in the wired connector to MOTOR 1
when finished. For dual gate systems, DO
NOT connect the MOTOR 2 connector to
the control board yet. MOTOR 2 connector
will be connected at a later step.
NOTES:
• If for a dual gate system, prepare both actuator harnesses per these instructions.
• Note that connections are different for Pull-to-Open and Push-to-Open installations.
• If a gate moves in opposite direction from what is expected, reverse the motor power lead wiring
(red & black wires) for that motor.
IMAGE 2-1:
MOTOR (ACTUATOR) CONNECTORS
MOTOR 1
MOTOR 2
NOTE: Refer to 912L actuator (MX4685) or 816-X actuator (MX4684) manuals for
specific instructions and diagrams for wiring the actuator to the 936 control board.
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]