TABLE 9-1: LCD STATUS AND ERROR DISPLAY DESCRIPTIONS
FLASHING
Board in unlearned state.
SOLID
Learn button has been pressed and board ready for learn cycle. Pressing OK
button begins the learn cycle.
FLASHING
“Chasing Cursor” display is seen only during unlearned condition. Signifies
motor activation and gate motion. Also confirms display segments are
working at power up.
SOLID
Open limit is activated.
SOLID
Close limit is activated.
SOLID
System in idle state (no motor activation) and no close or open limit
activated. Also indicates BlueBUS devices detected and functioning.
FLASHING
Hard shutdown is active and the audible alarm sounds. Display may be
cleared by pressing Reset Button after obstruction is cleared from gate path.
FLASHING
BlueBUS scan error or no monitored safety devices detected. May be cleared
by pressing the Learn Button if a monitored safety device is connected.
FLASHING
No actuator(s) sensed during first learning phase. Clear by ensuring actuator
is plugged into board, then cycling power Off and then On.
FLASHING
External EEPROM failed read/write test.
FLASHING
Actuator encoder dropped out or failed during gate movement. Clear
by pressing any button. Repeating error may indicate a faulty encoder or
incorrect wiring.
9.2 LCD STATUS AND ERROR DISPLAYS