CBOX936
INSTALLATION AND PROGRAMMING MANUAL
23
1. The control board should already be powered from battery connection. If not, apply power per
INSTRUCTION 8.
2. There are separate OPEN and CLOSE limit LEDs for each input connector, MOTOR 1 and MOTOR 2.
Refer to IMAGE 11-1 for location of OPEN and CLOSE limit indication LEDs on the control board.
3.
If “Lr” is not already flashing in the LED display, press and hold the LEARN button for approximately
8-10 seconds or until “Lr” stops flashing, then release. “Lr” should now be flashing..
NOTE:
Before the learning process, gates should only move for as long as buttons are held down and
stop when buttons are released.
4. Press and hold down each button and ensure that the CLOSE LED lights up red when gate reaches the
close limit, and the OPEN LED lights red up once the gate reaches the open limit (FIGURE 11-1).
5. Press either the OPEN or CLOSE buttons on the control board till gate is in approximately the halfway
position.
6. For a dual gate system, unplug the primary actuator, plug in the secondary actuator and repeat steps
3 and 4, but do NOT push the OK button in Step 9 until BOTH actuator motors are connected to the
Control Board. (Cont.)
11
GATE LIMIT LEARNING PROCEDURE
MOTOR 1 “OPEN
LIMIT” LED (RED)
MOTOR 2 “OPEN
LIMIT” LED (RED)
MOTOR 1 “CLOSE
LIMIT” LED (RED)
MOTOR 2 “CLOSE
LIMIT” LED (RED)
IMAGE 11-1:
OPEN/CLOSE LIMIT LED LOCATIONS
www.ApolloGateOpeners.com | (800) 878-7829 | [email protected]