CBOX936
INSTALLATION AND PROGRAMMING MANUAL
41
10.3 ACCESSORY OUTPUTS
FIRE INPUT
Normally Open (NO) dry contact input for use as a Fire Department control switch that opens and holds gate
open until the fire input is removed.
BLUEBUS INPUT
2-wire non-polarized connection to BlueBUS enabled accessories. Provides monitored sensor input.
AUXILIARY INPUT “C”; PROGRAM OPTION “P1”
This connector may be programmed (in OPTIONS) to accept 300 Hz pulse safety devices (safety or entrapment)
or, by default, be used as a step-by-step input. This connector features 12VDC, 3A power output that may be
used to power external devices.
Refer to FIGURE 10-1 and 10-2 for locations of the accessory outputs, which are described below.
OPEN OUTPUT
Dry contact relay output (SPDT), with Normally Open (NO), Normally Closed (NC) and common connections.
Active during open cycle and open limit activation.
CLOSE OUTPUT
Dry contact relay output (SPDT), with Normally Open (NO), Normally Closed (NC) and common connections.
Active during close cycle and close limit activation.
ALARM OUTPUT
Internally fused (0.5A) output to power alarm accessories. Fully programmable output.
SOLENOID LOCK OUTPUT
Internally fused (1.85A) output to power solenoid lock. Fully programmable output.
MOTOR BYPASS OUTPUT
Located between the MOTOR 1 and MOTOR 2 outputs this output provides power directly to the actuator(s)
while bypassing the control board. It is used for testing actuator motors. If actuator motor connector is plugged
into left & center pins (push-to-open configuration), the gate should open. If motor connector is plugged into
center & right pins, the gate should close. The opposite should happen for pull-to-open configuration.
NOTES:
•
In Standby Mode the voltage is inactive. DO NOT use to power entry/exit devices.
•
A “Step-By-Step” input is a type of command that opens-stops-closes-stops the gate with each press of
a button or other activation.