background image

2

– English

1) 

Warnings

This manual contains important information regarding safety. Before
you start installing the components, it is important that you read all the
information contained herein. Store this manual safely for future use.
Due to the dangers which may arise during both the installation and
use of the NiceHansa Robus, installation must be carried out in full
respect of the laws, provisions and rules currently in force in order to
ensure maximum safety. This chapter provides details of general warn-
ings. Other, more specific warnings are detailed in Chapters “3.1 Pre-
liminary Checks” and “5 Testing and Commissioning”.

According to the most recent European legislation, the

automation of doors or gates is governed by the provisions
listed in Directive 98/37/CE (Machine Directive) and, more
specifically, to provisions: EN 13241-1 (harmonised stan-
dard); EN 12445; EN 12453 and EN 12635, which enables to
declare the conformity to the machine directive. 

Please access “www.niceforyou.com” for further information, and
guidelines for risk analysis and how to draw up the Technical Docu-
mentation. This manual has been especially written for use by qualified
fitters. Except for the enclosed specification “Instructions and Warn-
ings for Users of the NiceHansa Robus gearmotor” which is to be
removed by the installer, none of the information provided in this man-
ual can be considered as being of interest to end users!
• Any use or operation of NiceHansa Robus which is not explicitly pro-

vided for in these instructions is not permitted. Improper use may
cause damage and personal injury.

• Risk analysis must be carried out before starting installation, to

include the list of essential safety requisites provided for in Enclosure
I of the Machine Directive, indicating the relative solutions employed.
Risk analysis is one of the documents included in the “Technical
Documentation” for this automation.

• Check whether additional devices are needed to complete the

automation with NiceHansa Robus based on the specific application
requirements and dangers present. The following risks must be con-
sidered: impact, crushing, shearing, dragging, etc. as well as other
general dangers.

• Do not modify any components unless such action is specified in this

manual. Operations of this type are likely to lead to malfunctions.
NICE disclaims any liability for damage resulting from modified prod-
ucts.

• During installation and use, ensure that solid objects or liquids do not

penetrate inside the control unit or other open devices. If necessary,
please contact the NICE customer service department; the use of
NiceHansa Robus in these conditions can be dangerous.

• The automation system must not be used until it has been commis-

sioned as described in chapter 5 “Testing and commissioning”.

• The NiceHansa Robus packing materials must be disposed of in

compliance with local regulations.

• If a fault occurs that cannot be solved using the information provided

in this manual, refer to the NICE customer service department.

• In the event that any automatic switches are tripped or fuses blown,

you must identify the fault and eliminate it.

• Disconnect all the power supply circuits before accessing the termi-

nals inside the NiceHansa Robus cover. If the disconnection device
is not identifiable, post the following sign on it: “WARNING: MAINTE-
NANCE WORK IN PROGRESS”.

• Only connect the control unit to a power supply line equipped with a

safety grounding system.

• The power supply line must be protected by circuit breakers.
• An isolator must be inserted in the power supply line from the electri-

cal mains mounted near the automation and must have a locking
system preventing unintentional unauthorized connection.

!

Particular warnings concerning the suitable use of this product in rela-
tion to the 98/37CE “Machine Directive” (ex 89/392/EEC): 
• This product comes onto the market as a “machine component” and

is therefore manufactured to be integrated to a machine or assem-
bled with other machines in order to create “a machine”, under the
directive 98/37/EC, only in combination with other components and
in the manner described in the present instructions manual. As spec-
ified in the directive 98/37CE the use of this product is not admitted
until the manufacturer of the machine on which this product is
mounted has identified and declared it as conforming to the directive
98/37/CE.

Particular warnings concerning the suitable use of this product in rela-
tion to the 73/23/EEC “Low Voltage” Directive and subsequent modifi-
cation 93/68/EEC:
• This product responds to the provisions foreseen by the “Low Volt-

age” Directive if used in the configurations foreseen in this instruc-
tions manual and in combination with the articles present in the Nice
S.p.a. product catalogue. If the product is not used in configurations
or is used with other products that have not been foreseen, the
requirements may not be guaranteed; the use of the product is pro-
hibited in these situation until the correspondence with the require-
ments foreseen by the directive have been verified by installers.   

Particular warnings concerning the suitable use of this product in rela-
tion to the 89/336/EEC “Electromagnetic Compatibility” Directive and
subsequent modifications 92/31/EEC and 93/68/EEC: 
• This product has been subjected to tests regarding the electromag-

netic compatibility in the most critical of use conditions, in the config-
urations foreseen in this instructions manual and in combination with
articles present in the Nice S.p.A. product catalogue. The electro-
magnetic compatibility may not be guaranteed if used in configura-
tions or with other products that have not been foreseen the use of
the product is prohibited in these situations until the correspondence
to the requirements foreseen by the directive have been verified by
those performing the installation.

Содержание Robus 250

Страница 1: ...NiceHansa Robus Instructions and warnings for installation and use 250 500...

Страница 2: ...be disposed of in compliance with local regulations If a fault occurs that cannot be solved using the information provided in this manual refer to the NICE customer service department In the event tha...

Страница 3: ...des the only data needed to determine whether the products of the NiceHansa Robus line are suit able for the intended application The structural characteristics of NiceHansa Robus make it suitable for...

Страница 4: ...r example for RB 500 if the leaf is 5 m long it will be possible to have 25 cycles hour and 13 consecutive cycles However if the leaf weighs 500 Kg they must be reduced to 75 resulting in 15 cycles ho...

Страница 5: ...1 power supply cable longer than 30 m may be used provided it has a larger gauge e g 3x2 5mm2 and that a safety grounding system is provided near the automation unit Note 2 If the BLUEBUS cable is lo...

Страница 6: ...ed in water or other liquids Keep NiceHansa Robus away from heat sources and open flames in acid saline or potentially explosive atmosphere this could damage NiceHansa Robus and cause malfunctions or...

Страница 7: ...n bring the bracket forward by at least 2 cm and secure it to the rack with the appropriate dowels The ideal distance of the bracket for inductive limit switches is between 3 and 8 mm as indicated in...

Страница 8: ...to collect together and join the cables which enter the gear motor Place the clamp just underneath the hole the cables enter through Make a hole in the rubber membrane which is slightly smaller than t...

Страница 9: ...the gearmotor with respect to the leaf If the leaf must move left for opening the selector must be moved towards left as shown in Figure 18 alternatively if the leaf has to move right during opening...

Страница 10: ...light flashes at a speed of 0 5 seconds on and 0 5 seconds off If present also check the flashes of the light connected to the S C A terminal slow flash es during opening quick flashes during closing...

Страница 11: ...pare the declaration of conformity of the automation system and deliver it to the owner 5 Prepare the Instructions and warnings for the use of the automa tion system and deliver it to the owner 6 Prep...

Страница 12: ...function is active the control unit will switch the BLUEBUS output and consequently the devices and all the LEDs off one minute after the end of the manoeuvre The only LED which will remain on is the...

Страница 13: ...conds between pressing one key and another If a longer period of time lapses the procedure will finish auto matically and memorize the modifications made up to that stage 1 Press the key Set and hold...

Страница 14: ...ED starts flashing L1 3 Press key or to move the flashing LED onto the input LED representing the parameter which is to be changed or 4 Press the key Set and hold it down during step 5 and 6 5 Wait ap...

Страница 15: ...e the key Set 7 Press the key four times to move the flashing LED to LED L5 L5 8 Press the key Set and hold it down during step 9 and 10 9 Wait approx 3 seconds until LED L5 representing the current l...

Страница 16: ...unit must go through the recognition process see paragraph 7 3 6 Recognition of Other Devices 7 3 4 FT210B Photo sensor The FT210B photo sensor unites in a single device a force limiting device type...

Страница 17: ...ted see table 7 The connection between NiceHansa Robus Master and NiceHansa Robus Slave is made via BlueBus In this case the polarity of the connections between the two NiceHansa Robus must be respect...

Страница 18: ...the recognition stage is completed L1 and L2 LED s will go off the STOP LED must remain on while L1 L8 LED s will light up according to the status of the relative ON OFF functions L1 L2 After you have...

Страница 19: ...h if 10 of the manoeuvres hasn t been reached 8 Release the key Set Table 17 control of the number of manoeuvres performed Example Manoeuvre counter reset After the maintenance of the system has been...

Страница 20: ...roximately 10 30Vdc if there is voltage the problem is due to the lamp in this case replace the lamp with one having the same characteristics if there is no voltage there may have been an overload on...

Страница 21: ...ry second When something is wrong the flashes are more frequent the light fla shes twice with a second s pause between flashes 6 flashes 1 second s pause 6 flashes At the starting of the manoeuvre the...

Страница 22: ...ormal operation the device indicates Stand by is not active During normal operation the device indicates Stand by is active Function programming in progress If it flashes together with L3 it means tha...

Страница 23: ...s suitable for the automation of gates featuring weights or lengths as shown in Tables 2 3 and 4 Durability Estimated between 20 000 and 250 000 cycles following the conditions indicated in table 4 Th...

Страница 24: ......

Страница 25: ...n devices that prevent movement if people or objects are in the way guaranteeing safe and reliable acti vation However children should not be allowed to play in the vicinity of automated systems to pr...

Страница 26: ...me seems not to work as well or not to work at all it may simply be that the battery is exhau sted depending on the type of use it may last from several months up to one year and more In this case you...

Страница 27: ......

Страница 28: ...10 06 2011 www nicehansa co za Nice Hansa SA 27 Davies Rd Malvern Germiston Tel Share Call 0860 642 672 Tel 27 11 615 0075 6 Fax 27 11 615 0083 info nicehansa co za...