English –
19
Control of the number of manoeuvres performed
The number of manoeuvres performed as a percentage on the set limit can be verified by means of the “Maintenance warning” function. Follow
the indications in table 17 for this control.
1.
Press the key
[Set]
and hold it down (approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press key
[
▲
]
or
[
▼
]
to move the flashing LED onto the input LED L7
representing the “Maintenance warning” parameter
or
L7
4.
Press the key
[Set]
,and hold it down during step 5, 6 and 7
5.
Wait approx. 3 seconds, after which the LED representing the current
level of the parameter “Maintenance warning” will light up
3s
6.
Press and immediately release the
[
▲
]
and
[
▼
]
keys.
and
7.
The LED that corresponds to the selected level flashes. The number of flashes indicates the percentage
of manoeuvres performed(in multiples of 10%) in relation to the set limit.
For example: with the maintenance warning set on L6 being 10000, 10% is equal to 1000 manoeuvres;
if the LED flashes 4 times, this means that 40% of the manoeuvres have been reached (being between
4000 and 4999 manoeuvres). The LED will not flash if 10% of the manoeuvres hasn’t been reached.
8.
Release the key
[Set]
Table 17: control of the number of manoeuvres performed
Example
Manoeuvre counter reset
After the maintenance of the system has been performed the manoeuvre counter must be reset. Proceed as described in table 18.
1.
Press the key
[Set]
and hold it down (approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press key
[
▲
]
or
[
▼
]
to move the flashing LED onto the input LED L7 representing the
“Maintenance warning” parameter
or
L7
4.
Press the key
[Set]
, and hold it down during step 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current
level of the parameter “Maintenance warning” will light up.
3s
6.
Press keys
[
▲
]
and
[
▼
]
, hold them down for at least 5 seconds and then release them.
The LED that corresponds to the selected level flashes rapidly indicating that the
manoeuvre counter has been reset
and
7.
Release the key
[Set]
Table 18: manoeuvre counter reset
Example
SSS
SSS
SSS
SSS
SSS
SSS
SSS
SSS
7.5 Connection of Other Devices
If the user needs to feed external devices such as a proximity reader
for transponder cards or the illumination light of the key-operated
selector switch, it is possible to tap power as shown in Figure 27. The
power supply voltage is 24Vdc -30% - +50% with a maximum avail-
able current of 100mA.
-
+
24Vcc
27
....
n=?