Start and stop
The boiler's burner is fully automatic and manages starting
and stopping itself if the control computer is connected
and has received the correct settings. For instructions about
settings prior to starting the boiler, see
Setting the control
computer
on page 20.
Start
Upon first start-up or if the fuel has finished and been
topped up, first allow fuel filling to run until the pellets
drop out of the flameproof hose. For instructions on how
to top up the pellet auger see
Pellet hopper and pellet
screw
points 6 - 9 on page 18.
1. To start the boiler press the main switch.
2. To start the burner, hold in the control computer's
ON/OFF
button for at least 3 seconds.
3. 2 stages of cleaning are performed before the burner
is lit. (Default setting, can be set between 2–5.) The
control computer's menu displays boiler status
CLEANING
.
4. When the cleaning is finished the start process contin-
ues.
A
The control computer displays
LIGHTING
B
Pellets are fed into the burner for the set time
(default setting 50 seconds).
C
Lighter and burner fan are started.
D
The photo cell registers when the pellets are lit
and shuts off the ignition pod.
E
The start-up process begins and the menu displays
START-UP
. This process takes 3 minutes and means
that the fan speed and fuel supply increase
gradually.
F
At the end of the start-up process the boiler
switches to the set control program.
TIP
Normal firing up takes approx. 9 minutes. If during
this time the photocell does not register any flames
the lighter will attempt to light a maximum of 5 times.
If no flames are registered after 5 attempts an alarm
is given and the firing up attempt is stopped.
Stop
1. To stop the burner, hold in the control computer's
ON/OFF
button for 3 seconds.
2. The menu displays
SHUTDOWN
.
3. The fuel feed is shut off.
4. The burner fan operates until no flames can be re-
gistered.
NOTE
The control computer does not control the heat pump
circulation pumps when the boiler is stopped in this
way.
In order for the control computer to control the heating
system's circulation pumps, the simplified menu must be
used when stopping. This means that only the burner shuts
down, the control computer is still operational.
1. Go to the burner menu.
2. Press Enter.
3. Scroll to Settings using the Up or Down arrow.
4. Confirm using Enter.
5. Scroll to
Burner operation
and click Enter.
6. Use the Down arrow to change from Yes to No.
A
The stop sequence is started immediately.
B
The control computer still controls the heating
system's circulation pumps.
NOTE
Emergency stop
Switch off the boiler at the main switch. This means
that all processes are stopped.
Remember that the remaining fuel will not be extin-
guished but must burn out.