Dealing with malfunctions and maintenance
General
Alarm
In event of unacknowledged alarm the LED lights with a
continuous red light.
In event of an acknowledged alarm the LED on the control
computer lights with a flashing red light.
To see what has occurred, go in under the Alarm menu
where you will find an alarm code. For explanation of alarm
codes see page 41.
ENTER
ON/OFF
INFO
ESC
12:05
33.3
12:05
05
12:0
ON
LED lamp
TURNED OFF Tu
Pellet burner
Ensure that the pellet burner is always optimally adjusted
to obtain the best economy and minimum environmental
impact. Checking and adjusting is carried out by a specialist
and should be carried out before every firing season.
Circulation pump
Even if the circulation pump, for a longer period is set to
“OFF”, the boiler’s computer will run the pump for 3
minutes twice a day. This is so that the circulation pump
does not jam.
Sweeping
Fire regulations state at what intervals a boiler and its
chimney must be swept; contact a professional chimney
sweep for more information.
!
WARNING!
The current to the boiler must be switched off during
service and maintenance of the boiler and burner.
The boiler is equipped with automatic sweeping of the
flues, which means that manual sweeping of these is not
required between the chimney sweep’s normal visits. In
order to obtain the optimal efficiency with a modern and
correctly adjusted pellet burner the boiler’s other fire af-
fected surfaces should be cleaned/swept occasionally
between the chimney sweep’s visits.
Before the sweep visits, the hatch for any draft limiter must
be locked by turning the locking screw a quarter turn to
the side of the hatch. This is to prevent soot from entering
the boiler room when the chimney is swept. After sweep-
ing the hatch must be unlocked again. For more instruc-
tions see the sweeping chapter page 7.
REMEMBER:
When the door for the combustion chamber opens, all
current to the pellet burner is automatically cut. The hatch
must be fully closed in order for the burner to start incan-
descing.
Check the optimum setting of the burner flame through
the sight glass.
APH
At the bottom of the hearth there is a removable ash box
and a soot box. The ash box and soot box are generously
sized and have room for ash and soot from two month’s
normal firing.
NOTE
Ash can still contain glowing embers after a long
period of time. Therefore, always use a non-inflam-
mable container and protective gloves when empty-
ing ash and soot.
PELLUX 100
10
For Home Owners
Dealing with malfunctions and maintenance
Содержание PELLUX 100
Страница 1: ...INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB 1411 1 PELLUX 100 331139 PELLUX 100 APH...
Страница 2: ......
Страница 63: ...Burner 61 PELLUX 100 For the Installer Electrical circuit diagram...
Страница 74: ...PELLUX 100 72...
Страница 75: ......