Menu
Step
BURNER
18.
Check that the burner is instigated. Using the Up and Down
arrows, scroll to:
Burner
.
19.
Press Enter to open the burner menu.
20:54
BURNER
Settings
20.
Using the Up and Down arrows scroll to:
Settings
.
21.
Press Enter to open the settings menu.
20:54
Burner on
BURNER
Fuel type
Feed fuel now
No
Yes
pellets
22.
Set
Burner on
to Yes.
This is the minimum of what must be activated and set for
the boiler to be started safely.
Depending on which accessory you have for your boiler,
there are other values that must be activated and this is
done as follows. E.g. Number of heating circuits, Number
of HW circuits etc.
Default setting burner
Go to Burner/Service in the control computer's menu and
set these values.
Value
Menu
15
Amount of air min (30%)
30
Amount of air max (100%)
7,3
Supply max (100%)
30
Power min (FL2)
100
Power max (FL2)
FL2
Modulation type
50
Photocell
12 gr
Fuel weight
5,5
Heating value
14
Amount of oxygen min (30%)
8
Amount of oxygen max
(100%)
50 seconds
Start dose
180 minutes
Sweeping period
2
Sweeping cycles