6. Reinstall the front panel.
7. Shut the boiler door. The door is equipped with a switch (door
sensor) that means that the boiler cannot be started if the door
is open.
8. Connect the power supply again.
9. Start the control computer.
Resetting the burner temperature limiter
!
WARNING!
This work may only be carried out by authorised
personnel!
The temperature limiter is accessible behind the protective
panel.
APH
Temperature limiter
1. Disconnect the power supply to the boiler.
2. Remove the 4 screws holding the protective panel in
position.
3. Press in the metal catch on the temperature limiter.
4. Reinstall the protective panels.
5. Connect the power supply again.
6. Start the control computer.
57