IMPORTANT
Excessive cranking can damage the starter motor. Do not crank the generator more than 30 seconds at a time,
and allow at least two minutes before trying again if the first attempt fails.
4. To stop the generator, press the rocker switch to the STOP position.
CAUTION
Failure to turn off the 120 volt appliances when starting or stopping the generator may damage the transfer
switch and/or electrical appliances.
DIESEL GENERATORS
The generator in your coach runs on the same diesel fuel as
your main engine. The diesel fuel is drawn through a
separate supply tube that is positioned in the tank in a
manner that will not allow the generator to draw fuel and run
if the tank level dips below the ¼ level.
Depending on the ambient temperatures, the generator may
pre-heat prior to cranking. This pre-heat condition is noted
by flashing the light on the generator start switch until the
cycle is complete (up to 15 seconds). Once it has pre-
heated sufficiently, the starter will engage and the engine
will start.
NOTICE
If your coach contains an Energy Management System, 8kw generator, and three roof air conditioners, the
combined load may exceed the capabilities of the generator. Please remember to turn off one of the air
conditioners as the 8kw generator is not intended to run all three roof air conditioners at the same time.
WARNING
It is critical that the AGS system be turned off any time the generator is going to be serviced. Failure to
deactivate the AGS system may result in damage, injury, or death if the Genset should start unexpectedly.
Also, if the AGS system is set and the generator is turned off at any switch, it will clear the AGS settings.
GAS GENERATORS
The generator in your coach& runs on the same fuel as your
main engine. The fuel is drawn through a separate supply
tube that is positioned in the tank in a manner that will not
allow the generator to draw fuel and run if the tank level
dips below the ¼ level.
FOR MORE INFORMATION
Refer to the product manufacturer's owner's manual and
links in Newgle to learn more about your coach's generator.
© 2018 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
63