CLIMATE ZONE
When enabled, this function will cause the generator to automatically run based on the individual HVAC zone demand.
The climate zone AGS function will automatically start and stop the generator. The generator will not automatically start
if shore power is present. Newmar sets this value to "LvRm," "Kitch," and "Bed."
PAGE 2
Page two allows you to change the autocharger and topoff
settings using the UP and DOWN arrows.
AUTOCHARGER START VOLTS (DC
VOLTAGE)
This setting determines the voltage level which
automatically starts the generator. When the AGS is
enabled and the house battery voltage drops below this
value for approximately two minutes, the generator will
automatically start and run until the charger switches to
Float Mode or the autocharger Max Run Time setting time
has expired. Newmar sets this value to "11.8 V" on all
coaches except for the King Aire. Newmar sets this value to
"12.0 V" on King Aire coaches.
AUTOCHARGER MAX RUN TIME
This setting controls how long the generator will run when it
is started by the autocharger function. Newmar sets this value to "240 Minutes."
TOPOFF VOLTS (DC VOLTAGE)
This setting determines the voltage level which will automatically start the generator based on the topoff run time
settings. Newmar sets this value to "12.5 V."
TOPOFF RUN TIME
This setting determines the amount of time before quiet time begins to automatically start the generator. It will run if the
autocharger function is enabled and the house battery voltage is below the topoff volts setting. Newmar sets this value
to "45 minutes."
PAGE 3
Page three allows you to change the settings for quiet time,
chassis start volts, and charge bridge duration using the UP
and DOWN arrows.
QUIET TIME
This feature allows the user to select when to begin and end
quiet time. During this time period, the generator will not
start for any reason. Newmar does not set this function to
any specific time.
CHASSIS START VOLTAGE
The chassis start voltage sets the DC voltage
which automatically starts the generator from a low chassis
battery voltage. Newmar sets this value to 12.3 V.
CHARGE BRIDGE DURATION
This displays the amount of time the generator will run when
the AGS is engaged with a low chassis battery bank. Newmar sets this value to 60 minutes.