IMPORTANT
Changing these control settings to improper values
can adversely affect the operation of the control
system and may cause damage to the coach.
MAX CHARGE RATE
This is the current charge rate of the Inverter. It is set from the factory to 70 percent. It will ramp up or drop down the
charge rate depending on the power available. This sets the percentage of the maximum DC output current that is
available to the charger. The maximum DC output current for the Freedom SW 3012 is 150 amps at 100 percent.
DESIRED MODE
This is the current mode of the inverter at any given time (off, operating, or standby).
ADVANCED SCREEN
This screen is password protected to allow Qualified
Service Technicians access to make changes to the control
settings.
EQUALIZE BUTTON
This button will take you to a screen to equalize your
batteries. AGM batteries are standard in 2019 New Aire,
Essex, and King Aire coaches and in all-electric London
Aire and Mountain Aire coaches.
YES, I MEANT IT.
Pressing this button will activate the equalize charging
process.
OOPS! GO BACK.
Pressing this button will allow you to return to the
Inverter
#1
screens.
WARNING
Newmar recommends that the Equalize function be performed at a Newmar Certified Service Center on liquid
lead acid batteries only! You should never equalize AGM batteries, as damage to AGM batteries may occur.
BACK BUTTON
This will take the user back to the
DC Power
main screen.