© 2020 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
81
ELECTRICAL
VIEWING INFORMATION DURING
BATTERY MODE
The LCD screen displays Inverter information as well
as feature settings in coordination with the LED lights
alongside the screen.
•
Press the Scroll UP button to toggle between the
following basic information:
INPUT VOLTAGE/OUTPUT VOLTAGE
•
Default screen
•
Shore power voltage = 80V
•
Output voltage = 120V
BATTERY VOLTAGE/BATTERY
DISCHARGE CURRENT
•
Battery voltage = 13.1V
•
Battery discharge current =
80A
LOAD PERCENT
•
Load = 20%
WARNING/FAULT
•
If a fault or warning is
detected, this screen
becomes the default screen.
•
Error code = E02 “DC Input
Over Voltage shutdown”
Idle Mode
When there is no AC output such as when an error or fault
condition is detected, the Idle Mode is displayed on the
LCD Screen. An example is shown below:
For definitions on battery capacity, load level, and error
code indicators, refer to the “LCD Screen Icons” section.
Turning Inverter Operation On
and Off
There are two ways to operate the Freedom X’s inverter.
•
Press the inverter Power button to a down position (it
is O
ff
in the up position).
•
When the inverter’s Ignition Control feature is set to
Auto-on, and the Ignition Control switch is enabled
and, a +12VDC signal is present.
Checking Battery Status
During inverter operation (in battery mode), you can
check the battery status by observing the battery capacity
indicator on the LCD screen. The battery voltage appears
in the left side of LCD screen. The normal operating
battery voltage range is between 11 and 15 volts.
Checking Output Power
When the inverter is in operation (in battery mode),
you can check how much power (displayed in Amps)
the Freedom X is supplying to the connected loads by
observing the load capacity indicator on the LCD screen.
The battery discharge amperage appears in the right side
of the LCD screen.
Operating Several Loads At
Once
If you are going to operate several loads from the
Freedom X, turn them on one at a time after you have
turned the inverter on. Turning loads on separately helps
to ensure that the inverter does not have to deliver the
starting current for all the loads at once, and will help
prevent an overload shutdown.
To prevent unnecessary battery discharge, press the
inverter Power button to turn it o
ff
when you are not using
the Freedom X.
WARNING
!
ELECTRICAL SHOCK HAZARD: Turning the inverter
Power button o
ff
does not disconnect DC battery
power from the Freedom X. You must disconnect
both AC and DC power before working on any
circuits connected to the unit. Failure to follow these
instructions can result in death or serious injury.
Turning The Audible Alarm On
or Off
The Freedom X’s audible alarm can be silenced. Any
warnings such as fault conditions or imminent shutdown
are both displayed on the LCD screen and sounded on
the alarm speakers. It is not possible to turn OFF the
screen and prevent it from displaying error codes but it is
possible to turn OFF the audible alarm.
To reset the alarm:
•
Press the inverter Power button to turn it O
ff
(from a
down position to up) and press again to turn it On to
reset an active alarm and clear the fault.
Resetting AC Output
The 15 amp resettable breaker is located on the inverter
near the outlet.
Содержание Canyon Star 2021
Страница 1: ...2021 sm ...