![background image](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366059.webp)
1-1-06, CO/PBX Incoming Ringing Alarm Time Selection
DRAFT 3
Chapter 1 – 39
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
1-1-06
System Mode
1
Submode
1
Data No.
06
PC Programming
+ BM
CO/PBX Incoming Ringing
Alarm Time Selection
General Description
Use this Memory Block to specify the time interval between the time a CO/PBX call is detected
and the time the ringing tone changes to a higher pitch when the call is not answered. If No Limit
is selected, the ringing tone does not change.
With IPK R2000 and above,
this memory block allows flexible entries and has four classes.
For R2000 only.
For R2000 and above.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates the
default setting.
10 sec.
20 sec.
30 sec.
∞
LK 5
LK 6
LK 7
LK 8
Display
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK1 +
KF
to access the Memory Block.
3
Use the dial pad to enter the time required.
Note
:
J
to move cursor left.
L
to move cursor right.
Setting Data (Allow):
000 to 255 sec
000 = No Limit
Default values:
Class 1 to Class 4 = 60 secs
4
Press
N
to write the data.
5
Press
P
to go back on-line.
0 6 : R I N G
A L M
∞
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
0 6 : R I N G
A L M
0 0 0
s
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data