![NEC XEN IPK DIGITAL TELEPHONE Скачать руководство пользователя страница 307](http://html.mh-extra.com/html/nec/xen-ipk-digital-telephone/xen-ipk-digital-telephone_programming-manual_248366307.webp)
1-14-04, ACR Trunk Group to Route Number Assignment
DRAFT 3
Chapter 1 – 287
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
1-14-04
System Mode
1
Submode
14
Data No.
04
PC Programming
+ AB
ACR Trunk Group to Route
Number Assignment
General Description
Use this Memory Block to specify whether a Trunk Group is used for each Route assignment.
Display
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded selection
is the default.
NORMAL
(Originate)
TKGP
(01~32)
RAB
(01~32)
ICM
Programming Procedures
1
Go off-line.
2
Press LK1 + LK14 +
L
D
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the Setting Data 1 option.
Use dial pad keys
K
~
I
to select Data Setting Data 2 Trunk Group Number (01~32) or Setting Data 2 RAB (1~16).
Note:
Press
J
to move cursor left.
Press
L
to move cursor right.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
3-03
Trunk-to-Trunk Group Assignment
4-40
LCR Class Selection
1-8-08
Class of Service (Station) Feature Selection 2
1-14-00
ACR Feature Allow/Deny Selection
1-14-01
ACR Dialling Assignment
1-14-02
ACR Dialled Number Dial Allow/Deny Selection
1-14-03
ACR Route Table Number Assignment
1-14-05
ACR Digit Delete Assignment
1-14-06
ACR Digit Add Assignment
N
If NORMAL is selected, the call is routed to Trunk Group 1 exactly as dialled.
0 4 / 0 1 = N O R M A L
T I M E
D I S P L A Y
Data
No.
Setting
Data 1
Route
No.
Setting
Data 2