1-8-33, Master Clock Selection
DRAFT 3
Chapter 1 – 247
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
1-8-33
System Mode
1
Submode
8
Data No.
33
PC Programming
+ AN
Master Clock Selection
General Description
When either a PRT(1)-U( ) or BRT(4)-U( ) ETU is installed, clocking must be synchronised.
This Memory Block assigns the source to be synchronised with. Enter the cabinet/slot number of
the PRT or BRT ETU to be used for synchronisation of the CLKG-U( ). This synchronised clock
signal is then fed to each of the remaining BRT and PRT ETUs.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK8 +
CC
to access the Memory Block.
3
Use dial pad to enter number of digits.
Note:
Use the following to enter data:
K
~
I
to enter digits
J
to move cursor left
L
to move cursor right
Default Values
Cabinet 0 (Not Assigned)
Setting Data
Cabinet 0 ~ 3
Slot 1 ~ 8
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Card Interface Slot Assignment
N
1. If the master clock selection is changed, all PRT calls may be disconnected as the resynchronisation occurs.
2. When a PRT or BRT ETU is installed, a CLKG-U( ) Unit must be fitted to the CPUI( )-U( ) ETU.
3. Ensure this Memory Block is set correctly when a BRI or PRI card is installed.
4. If Clock is not set, data services via ISDN may be affected.
3 3 : M S T R C L C K
0 :
T I M E
D I S P L A Y
Data
No.
Title
Cabinet
0~3
Slot 1~8