3-64, DIT Night Mode Delay Answer Enable
DRAFT 3
Chapter 1 – 395
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
System Mode
3
Submode
—
Data No.
64
PC Programming
+ BCT
DIT Night Mode Delay
Answer Enable
General Description
This Memory Block is used to specify whether or not the DIT Delay Answer Timer shall apply to
CO/PBX calls received when the system is in Night Mode.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
No
Yes
LK 5
LK 6
LK 7
LK 8
Programming Procedures
1
Go off-line.
2
Press LK3 +
N
+
DD
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
R
to go to the next CO/PBX Line No.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
DIT Delay Answer Timer Selection
N
1. The DIT Delay Answer Time specified in MB , 3-62 shall apply for this purpose.
2. If set to YES, incoming CO/PBX calls during Night Mode will ring for the duration specified in MB , 3-62 before
changing to DIT status.
3. If set to NO, incoming CO/PBX calls during Night Mode will immediately change to DIT status regardless of the setting
in MB , 3-52.
4. This setting only applies to those CO/PBX lines assigned with the DIT facility in MB , 3-44 and MB , 3-45.
1 1 / 6 4 :
N T M O D
N 0
T I M E
D I S P L A Y
CO/PBX
No.
(01~64)
Data
No.
Title
Setting
Data