1-1-34, Tie Line First Ring Pattern Selection
DRAFT 3
Chapter 1 – 71
Xen IPK
Programming Manual
Doc. No
.: 8194 -
Rele
ase 2.
0
December
2004
1-1-34
System Mode
1
Submode
1
Data No.
34
PC Programming
+ ALN
Tie Line First Ring Pattern
Selection
General Description
Use this Memory Block to set specific ringing tones for incoming calls on Tie lines. After a delay
interval specified in Memory Block 1-1-07
Tie Line Delay Ringing Timer Selection
, a Tie call can
ring at all Day/Night ring-assigned telephones using a different cadence.
Display
Settings
LK 1
LK 2
LK 3
LK 4
The shaded area indicates
the default setting.
Pattern 1
Pattern 2
Pattern 3
Pattern 4
LK 5
LK 6
LK 7
LK 8
ICM
Voice
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
CD
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
Tie Line Delay Ringing Timer Selection
Tie Line Delay Ring Pattern Selection
CO/PBX Ring Assignment (Day Mode)
CO/PBX Ring Assignment (Night Mode)
N
1. Specify one pattern in the Ringing Pattern Selection Table.
2. If Voice is selected, switching from voice to tone is not allowed, Memory Block
is not used, and Handsfree
Answerback is not allowed at the receiving station.
3 4 : T L I
R N G
P A T 3
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data