CHAPTER 10 SERIAL INTERFACE FUNCTION
255
(d) When loss occurs due to restart condition during data transfer
<1> Not extension code (Example: matches with SVA0)
ST
AD6-AD0
RW
AK
D7-Dn
ST
AD6-AD0
RW
AK
D7-D0
AK
SP
▲
1
▲
2
∆
3
▲
1 : IICS0 = 1000X110B
▲
2 : IICS0 = 01000110B (Example: when ALD is read during interrupt servicing)
∆
3 : IICS0 = 00000001B
Remarks
▲
: Always generated
∆
: Generated only when SPIE = 1
X : don’t care
Dn = D6-D0
<2> Extension code
ST
AD6-AD0
RW
AK
D7-Dn
ST
AD6-AD0
RW
AK
D7-D0
AK
SP
▲
1
▲
2
∆
3
▲
1 : IICS0 = 1000X110B
▲
2 : IICS0 = 0110X010B (Example: when ALD is read during interrupt servicing)
IICC’s LREL is set to “1” by software
∆
3 : IICS0 = 00000001B
Remarks
▲
: Always generated
∆
: Generated only when SPIE = 1
X : don’t care
Dn = D6-D0