Chapter 1 - Installing the Chassis
Chapter 1
1 - 3
S
ECTION
1-2
Equipment Overview
1.2.1
System Chassis
There are three types of chassis:
●
9 1/2” base Chassis-B
●
9 1/2” expansion Chassis-E
●
19” Chassis-A
The first chassis (the Controlling Chassis-B with CCPU) provides 3 slots and a power supply. One slot in the
first chassis (Controlling Chassis) is used for the CCPU. Each expansion chassis (Chassis-E) provides 3 slots.
In a networked system using CygniLink and an IP connection, a second CCPU can be used for a CCPU Fail-
Over feature (primary/secondary CPUs) as a backup in case of a hardware or power failure. (The CCPUs must
be programmed for primary/secondary operation.)
To expand the system further, additional chassis can be added. Each Chassis-B can be combined with an
expansion chassis (Chassis-E) - the Chassis-B providing the power to the expansion chassis. A Chassis-B or
combined Chassis-B / Chassis-Es can be added. These chassis are then interconnected, for a maximum of 4
combined hard-wired Chassis-Bs and 4 Chassis-Es.
In place of combining a Chassis-B and Chassis-E to make a 19” chassis, you can use the 19” Chassis-A. This
chassis provides 6 slots and a power supply. The first slot in the chassis is used for the CCPU. The remaining
slots can be used for the various system blades required.
Up to 4 combined Chassis-B/Chassis-E or 19” Chassis-A can be connected locally. However,
in order to reach the system
’
s maximum port capacity, additional chassis (either combined
Chassis-B / Chassis-Es or the 19” Chassis-A) must be added - connected by a VoIP
connection.
Figure 1-1: Expansion Options
9.5”
3 slot
1 Main Chassis
32 ports
80 ports
160 ports
320 ports
512 ports
6 slot
1 Main Chassis
12 slot
2 Main Chassis
24 slot
4 Main Chassis
19”
19”x2
19”x4
IP Expansion
IP connection
Содержание UX5000
Страница 12: ...x Table of Contents Table of Contents...
Страница 18: ...1 6 Chapter 1 Chapter 1 Installing the Chassis...
Страница 26: ...1 14 Chapter 1 Chapter 1 Installing the Chassis...
Страница 80: ...1 68 Chapter 1 Chapter 1 Installing the Chassis Figure 1 90 19 CHASSIS A RACK MOUNT INSTALLATION...
Страница 84: ...1 72 Chapter 1 Chapter 1 Installing the Chassis...
Страница 90: ...2 4 Chapter 2 Chapter 2 Blade Installation and Startup...
Страница 98: ...2 12 Chapter 2 Chapter 2 Blade Installation and Startup...
Страница 113: ...Chapter 2 Blade Installation and Startup Chapter 2 2 27 Figure 2 11 EXIFU CABLING...
Страница 118: ...2 32 Chapter 2 Chapter 2 Blade Installation and Startup Figure 2 15 INTRAMAIL COMPACT FLASH CARD...
Страница 144: ...2 58 Chapter 2 Chapter 2 Blade Installation and Startup...
Страница 172: ...2 86 Chapter 2 Chapter 2 Blade Installation and Startup...
Страница 174: ...2 88 Chapter 2 Chapter 2 Blade Installation and Startup...
Страница 208: ...4 14 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 212: ...4 18 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 220: ...4 26 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 222: ...4 28 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 224: ...4 30 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 226: ...4 32 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 228: ...4 34 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 254: ...4 60 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 260: ...4 66 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 274: ...4 80 Chapter 4 Chapter 4 Terminals and Optional Equipment...
Страница 284: ...5 4 Chapter 5 Chapter 5 LAN Connection...
Страница 332: ...vi Index Index...