PRG 13-04-03: 3; Transfer mode set “Remote monitor”.
PRG 13-04-04: 200; Set monitored terminal number.
PRG 15-07-01: Set “
#
03” to
Function
key.
To start Room Monitor
1.
Press
Speaker
key + dial
610
+
1
+ monitored terminal number, “200” and press
Speaker
key.
- OR -
Press the
Function
key (
#03
) + dial
1
+ monitored dial number, “200” , the
Function
key turn on
Red (slow flash), and press
Speaker
key.
2.
Place incoming call from telephone which number is set at PRG 13-04-01.
3.
Room Monitor start at extension 200.
4.
By dialing
*
from outside it is possible to make both way talk.
To stop Room Monitor
1.
Press
Speaker
key + dial
610
+
0
+ monitored terminal number, “200”.
- OR -
Press the red flashing
Function
key (
#03
) + dial
0
+ monitored dial number, “200”.
2.
Place outside call from telephone which number is set at PRG 13-04-01.
3.
Call ring at extension 200.
Remote Inspection
< Program >
PRG 11-10-49: 619; Auto Dial Setting for Remote
PRG 20-45-01: 200; Remote Inspection terminal, 200
PRG 20-45-02: 12:00; Ringing start time, 12 o’clock noon
PRG 20-45-03: 3; ringing continue time, 3 minutes
PRG 20-45-04: 999; Speed dial bin number, 999
PRG 20-45-05: 1; VRS message number when inspected extension answered, 1
PRG 20-45-06: 2; VRS message number when emergency call destination answered, 2
PRG 20-45-07: 3; Times of auto repeat dial, 3
PRG 20-45-08: 30; Auto dial calling time, 30 sec
PRG 20-45-09: 30; Interval of Auto Dial, 30 sec
Set up Remote Inspection
1.
Press
Speaker
key + dial
619
at Multiline Terminal.
2.
Dial Remote Inspection terminal number (1-6).
3.
Dial 1 (set).
4.
Dial Remote Inspection extension number, “200”.
5.
Dial Ringing start time, “1200”.
6.
Dial ringing continue time, “03”.
7.
Dial Speed dial bin number to use, “999”.
8.
Dial emergency call destination number “xxx-xxx” and press
Hold
key.
9.
Dial VRS message number when inspected extension answered, “001”.
10. After beep tone, record the message and press
#
key.
11. Dial VRS message number when emergency call destination answered, “002”.
12. After confirmation tone, record the message.
13. Press
Speaker
key and finish recording.
ISSUE 2.0
SL1100
Features and Specifications Manual
1-659
S
Содержание SL1100
Страница 2: ......
Страница 3: ...Features and Specifications Manual A50 031169 003 NA ISSUE 2 0 ...
Страница 128: ...4 When the telephone rings lift the handset You hear the Hold tone 5 Hang up SL1100 ISSUE 2 0 1 116 Callback C ...
Страница 171: ...5 Press Speaker key to hang up ISSUE 2 0 SL1100 Features and Specifications Manual 1 159 C ...
Страница 218: ...2 Dial 724 SL1100 ISSUE 2 0 1 206 Dial Pad Confirmation Tone D ...
Страница 312: ...Operation While talking on a terminal handset 1 Press Mute key SL1100 ISSUE 2 0 1 300 Handset Mute Handset Cutoff H ...
Страница 392: ...Figure 1 21 Cascade Message Notification Flow Chart 1 SL1100 ISSUE 2 0 1 380 InMail Cascade Message Notification I ...
Страница 393: ...Figure 1 22 Cascade Message Notification Flow Chart 2 ISSUE 2 0 SL1100 Features and Specifications Manual 1 381 I ...
Страница 713: ...Operation Refer to the SL Desktop Suite Manual ISSUE 2 0 SL1100 Features and Specifications Manual 1 701 S ...
Страница 741: ... Direct Inward Dialing DID ISSUE 2 0 SL1100 Features and Specifications Manual 1 729 T ...
Страница 856: ...MEMO SL1100 ISSUE 2 0 2 26 Codes Tables ...
Страница 862: ...MEMO SL1100 ISSUE 2 0 3 6 Features Availability by Software Revision ...
Страница 863: ...MEMO ISSUE 2 0 SL1100 Features and Specifications Manual 3 7 ...
Страница 864: ...Features and Specifications Manual NEC Corporation ISSUE 2 0 ...