8.4 Replacement of Controller
If a controller becomes defective, the SERVICE LED on the array controller lights orange. In addition,
the FAULT LED on the controller lights orange. The defective controller may be replaced with anew
one with the power of the disk array unit remaining ON.
If a cache memory or DE port installed in the controller becomes defective, the SERVICE LED on the
relevant array controller and the FAULT LED on the controller are lit.
If so, replace all the cache memories and DE ports as well as the controller or contact your
maintenance service representative to identify the defective unit for replacement.
<Replacement procedure>
1.
Identify the defected controller with the FAULT LED on the controller being lit.
Remove all the cables connected to the defective controller. Write down the connections
between the cables to be removed and the mating connectors.
2.
Loosen a screw securing the ejector of the target controller, open the ejector pulling it by 90º,
and then pull out the controller. (When the controller is pulled out, the protection shutter in
the unit closes and it is locked.)
Be careful this may be hot.
Содержание NF2900-SR40E
Страница 8: ...v ...
Страница 9: ...vi ...
Страница 10: ...vii ...
Страница 13: ...x NF2900 SR40E ...
Страница 24: ...7 ...
Страница 43: ...26 ...
Страница 52: ...35 Sample configuration 1 NF2900 SR40E NF2900 SP02E NF2500 SE42E 16 ...
Страница 65: ...48 capacity and rotational speed be used together ...
Страница 76: ...59 Be careful as this may be hot ...
Страница 80: ...63 Note The figure above indicates the addition of NF2900 SC01E ...
Страница 133: ...116 DE Location View DE00 DE01 DE05 DE09 DE0 DE0 DE04 DE08 DE03 DE07 DE0 DE0 DE02 DE06 DE0 DE0 ...
Страница 134: ...117 1 2 5 Network Property Select 4 Configuration 7 Network Property to set the following items ...