Connect or remove a peripheral device from the disk array unit after turning off all
the power supplies of the disk array unit and peripherals and pulling out the power
cords from the AC outlets. If not, some units may be broken and/or you may be
electrically shocked.
To carry or reinstall the disk array unit, disconnect all cables and power cords
beforehand. If not, some units may be broken, you may be electrically shocked,
and/or a fire may occur.
Handle optical fibers carefully and gently.
The minimum bending radius of optical fiber shall be 30 mm.
Dust and/or dirt may attenuate the optical power of optical fiber causing data errors
to occur. Clean any optical fiber cable whenever it is inserted into the mating
connector with the following procedure.
1. Blow parts cleaning gas (e.g. compressed air) to the connector of the optical fiber
cable for several seconds.
2. Wipe the connector with a non-woven cloth soaked with alcohol for several passes.
3. Apply the compressed air to the connector again.
To install the unit in a rack, observe the following guidelines.
1. TMRA – If installed in a rack, consideration should be given to installing the
equipment in an environment compatible with the TMRA.
2. Reduced Air Flow – Installation in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
3. Mechanical loading – Mounting of the equipment in the rack should be such that a
hazardous condition is not created due to uneven mechanical loading.
4. Circuit Overloading – Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
5. Reliable grounding – Reliable grounding of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g., use of power strips).
Notes on Disposal
Содержание NF2900-SR40E
Страница 8: ...v ...
Страница 9: ...vi ...
Страница 10: ...vii ...
Страница 13: ...x NF2900 SR40E ...
Страница 24: ...7 ...
Страница 43: ...26 ...
Страница 52: ...35 Sample configuration 1 NF2900 SR40E NF2900 SP02E NF2500 SE42E 16 ...
Страница 65: ...48 capacity and rotational speed be used together ...
Страница 76: ...59 Be careful as this may be hot ...
Страница 80: ...63 Note The figure above indicates the addition of NF2900 SC01E ...
Страница 133: ...116 DE Location View DE00 DE01 DE05 DE09 DE0 DE0 DE04 DE08 DE03 DE07 DE0 DE0 DE02 DE06 DE0 DE0 ...
Страница 134: ...117 1 2 5 Network Property Select 4 Configuration 7 Network Property to set the following items ...