112
Set the Target ID Configuration of individual specification.
Port Indicates
port
positions.
Link Attach
Specify link topology. (Select a proper value from the pull-down menu.)
0:FC-AL or Fabric
2:Only FC-AL
3:Only Fabric
Select "2" or "3."
Mode
Indicates the bit meaning on the screen (with a hexadecimal number). The
following two modes can be set currently. Set either one.
Host Director Port
: 0000
Replication Director Port : 0040
Switch
Provide a setting for your Switch.
See Table 1.2.2 for the additional rule on loop ID.
See Table 1.2.1 for the relation between the Switch setting value and AL_PA.
Data Rate
Set the data rate of the FC link. (Select a proper value from the pull-down
menu.)
0:Auto Negotiate
8:1Gbps
9:2Gbps
A:4Gbps F:Undecided
Select "8" or "9."or”A”
AL_PA Indicates
AL_PA.