The host system cannot recognize the disk array unit.
Cause Countermeasures
The FC cable is not connected correctly.
Connect the FC cable correctly according to Chapter
5 "Connection of Disk Array Unit".
After turning on the power switch of the
host system or FC-AL switch, the power
of the disk array unit is turned on.
See Section 7.2 "Power On/Off of Disk Array Unit".
Each AL-PA must be unique. The same
AL-PA is specified in duplicate.
Set an AL-PA different from the AL-PAs of other FC
devices in the loopaccording to Chapter 5
"Connection of Disk Array Unit".
The setting of a host bus adapter or
FC-AL switch is incorrect.
Set the switches correctly according to the User's
Guide of the host bus adapter or FC-AL switch, the
host system, and/or additionally installed peripherals.
The used host bus adapter is unavailable
for the disk array unit.
Use the host bus adapter available for the disk array
unit. Contact your sales representative if unknown.
The disk array unit is installed in an area
in which it easily suffers vibration and/or
shocks.
Install the disk array unit referring to Chapter 1
"Notes on Installation and Handling of Disk Array
Unit".
The power is turned off or the reset
button on the host system is pressed with
the ACCESS LED (green) being on.
Contact your service representative.
The logical disk of the disk array unit is
not assigned.
Assign the logical disk number appropriately using
the " NEC Storage Manager software" or contact
your service representative.
8.2 Computer Virus
A computer virus is a program that is intentionally designed to cause damage to a third party's
programs or databases
The program can replicate itself or use another system function to infect other systems by copying
itself into other programs. The appearance of symptoms of virus infection can be delayed by having
the system wait for a specific point in time, a specific period of time, or a specific number of
transaction executions. The virus may destroy programs, data, or other files or causes systems to
operate in a way not intended by the designers.
To suppress the risk of damage to a minimum level, take proper measures such as a regularly
scheduled backup of important data.
Содержание NF2900-SR40E
Страница 8: ...v ...
Страница 9: ...vi ...
Страница 10: ...vii ...
Страница 13: ...x NF2900 SR40E ...
Страница 24: ...7 ...
Страница 43: ...26 ...
Страница 52: ...35 Sample configuration 1 NF2900 SR40E NF2900 SP02E NF2500 SE42E 16 ...
Страница 65: ...48 capacity and rotational speed be used together ...
Страница 76: ...59 Be careful as this may be hot ...
Страница 80: ...63 Note The figure above indicates the addition of NF2900 SC01E ...
Страница 133: ...116 DE Location View DE00 DE01 DE05 DE09 DE0 DE0 DE04 DE08 DE03 DE07 DE0 DE0 DE02 DE06 DE0 DE0 ...
Страница 134: ...117 1 2 5 Network Property Select 4 Configuration 7 Network Property to set the following items ...