Problem Solving 5-17
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B7C
The error occurred
during the redundant
power module
confirmation.
An error occurred while redundant
power supply was configured.
Contact your service representative to
replace the power unit.
0B7D
The normal
operation can not be
guaranteed with use
of only one PSU.
System is running on only one
power supply.
Contact your service representative to
replace the power unit.
0B80
BMC Memory Test
Failed.
BMC SRAM test error
0B81
BMC Firmware Code
Area CRC check
failed.
CRC error occurred in BMC code
area.
0B82
BMC Core Hardware
Failure.
Hardware failure occurred in BMC.
0B83
BMC 1BF or 0BF
check failed.
0B8A
BMC SEL area full
0B8B
BMC progress check
timeout.
0B8C
BMC command
access failed.
0B8D
Could not redirect
the console-BMC
busy.
0B8E
Could not redirect
the console-BMC
error.
0B8F
Could not redirect
the console-BMC
parity error.
Possible BMC errors.
0B90
BMC Platform
Information Area
Corrupted.
The platform information area of
BMC is damaged.
0B91
BMC update
firmware corrupted.
Possible BMC errors.
Shutdown and restart the server. If the
error cannot be corrected, contact your
service representative.
0B92
Internal use area of
BMC FRU corrupted.
Possible BMC errors.
All the commands and functions other
than the FRU command and the EMP
function can be used. This is not a fatal
error. Turn off the power once and
then on again to restart the server. If the
error cannot be corrected, contact your
service representative.
0B93
BMC SDR
Repository empty.
No BMC SDR data exists.
Turn off the power once and
then on again to restart the server. If the
error cannot be corrected, contact your
service representative.
Содержание EXPRESS5800/120Lf
Страница 1: ... U s e r s G u i d e EXPRESS5800 120Lf ...
Страница 2: ...NEC ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 120Lf ...
Страница 9: ...Contents vii ...
Страница 10: ...viii Contents ...
Страница 36: ...1 20 System Overview ...
Страница 99: ...Upgrading Your System 4 13 Figure 4 9 Replacing the Real Time Clock Battery ...
Страница 146: ...4 60 Upgrading Your System Figure 4 60 Installing a Power Supply ...
Страница 170: ...5 24 Problem Solving ...