Troubleshooting 7-17
Unavailable disks are displayed on Disk Management:
Follow the instruction below:
Disk Status
Description
Action
A message [Foreign] is
displayed when the dynamic
disk used on another system is
mounted.
[To use data of the disk]
Import the disk referring to Chapter 3
“Windows Setup and Operation.”
[To make the disk usable]
Initialization is required to use this
disk. Initialize this disk to convert it to
a usable disk.
<Note>
The data on disks are lost when
initialized. Make sure to back up the
data before initializing disks.
A message [Missing] is
displayed when the dynamic
disk is broken or removed.
Delete the mirror on the disk when
mirror volume is on missing disk.
After deleting the mirror, right-click
[Missing] disk and execute [Remove
disk].
A message
[Not Initialized] is displayed
when there is no signature on
the disk.
Right-click on the disk and execute
[Initialize Disk] to convert it to a usable
disk.
CPU load ratio of SNMP Service (snmp.exe) increases:
→
While monitoring the server from NEC ESMPRO Manager, the CPU load ratio of
SNMP Service on the NEC ESMPRO Agent side may increase at every monitoring
interval (default: 1 minute).
→
NEC ESMPRO Manager and NEC ESMPRO Agent exchange information through
SNMP Service. If the server status monitoring by NEC ESMPRO Manager is on
(default: ON), NEC ESMPRO Manager regularly issues a request to NEC ESMPRO
Agent to get the current status of the server. In response, NEC ESMPRO Agent
checks the status of the server. As a result, the CPU load ratio of SNMP Service
increases temporarily.
→
If you have trouble of terminating a movie player application, turn off the server
status monitoring by NEC ESMPRO Manager or extend the monitoring interval.
SNMP Service caused hang:
→
SNMP Service has a module called “SNMP Extended Agent.” This module may be
registered when you install some software that uses SNMP Service. If you start
SNMP Service, SNMP Extended Agent is also loaded at the initialization. However,
if the initialization is not completed within a specified period, SNMP Service will
hang. It may take time to complete the initialization due to temporary high load on
the system. In this case, wait for the system load become low enough before
restarting SNMP Service.
Содержание EXP320J
Страница 12: ... THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 25: ...xiii APPENDIX A SPECIFICATIONS A 1 APPENDIX B I O PORT ADDRESSES B 1 ...
Страница 26: ...xiv THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 28: ...1 2 Precautions for Use 使用上的注意 本章包含著對服務器恰當安全的操作必要的信息 ...
Страница 54: ...1 28 Precautions for Use This page is intentionally left blank ...
Страница 64: ...2 10 General Description Rear View ...
Страница 68: ...2 14 General Description CPU IO Module CPU IO module ...
Страница 88: ...2 34 General Description This page is intentionally left blank ...
Страница 100: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled ...
Страница 101: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner ...
Страница 218: ...4 92 System Configuration This page is intentionally left blank ...
Страница 253: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed ...
Страница 390: ...5 172 Installing and Using Utilities This page is intentionally left blank ...
Страница 408: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1 ...
Страница 410: ...6 20 Maintenance This page is intentionally left blank ...
Страница 454: ...7 44 Troubleshooting This page is intentionally left blank ...
Страница 485: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035 ...
Страница 500: ......
Страница 503: ......