7-36 Troubleshooting
Printer Information’s Available Time:
When you add a new printer, install its driver and make its settings, if you do not make settings for
the available time from the properties window of the printer, the printer’s available time (From and
To) in [Printers and Faxes] are [00:00], on the other hand, NEC ESMPRO Manager’s time are
[9:00]. To display them properly, make the settings of printer from its properties window. The
procedures are as follows:
1.
From [Control Panel], click [Printers and Faxes], and open the properties window of a printer
for making settings.
2.
Select the [Advanced] tab.
3.
Enter values in the available time (“Available from” and “To”), and click [OK] on the
properties window to exit.
Now, you can see the correct information from NEC ESMPRO Manager, too.
The disk related works are desired while NEC ESMPRO Agent is running:
→
The following works to disks (hard disk drive or magneto optical) are not allowed
while NEC ESMPRO Agent is running.
z
To format or delete a partition by Disk Administrator or by other means.
z
To request programmatically to remove media from removable disks such as
MO, Zip and PD.
Please conduct these works by following the procedure written below.
1.
Open [Control panel] – [Service].
2.
Select a service named “ESM Common Service” and click [Stop].
3.
Confirm that “ESM Common Service” is stopped, and close the [Service] in
[Control Panel].
4.
Do the disk–related works.
5.
Open the [Service] in [Control Panel] again. Select “ESM Common Service”
and click the [Start].
6.
Confirm that “ESM Common Service” is started and close the [Service] and
[Control Panel].
Changing the threshold of temperature/voltage/fan monitoring is desired:
→
Displaying/changing the threshold of the temperature/voltage /fan from NEC
ESMPRO Agent is not allowed. However, you can display the threshold on the
data viewer of NEC ESMPRO Manager on some models. NEC ESMPRO Agent
monitors using the appropriate threshold that is set for each model.
The detail information of alert is displayed as “Unknown”:
→
Detail information of some alert displayed on the alert viewer may be displayed as
“Unknown.”
Содержание EXP320J
Страница 12: ... THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 25: ...xiii APPENDIX A SPECIFICATIONS A 1 APPENDIX B I O PORT ADDRESSES B 1 ...
Страница 26: ...xiv THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 28: ...1 2 Precautions for Use 使用上的注意 本章包含著對服務器恰當安全的操作必要的信息 ...
Страница 54: ...1 28 Precautions for Use This page is intentionally left blank ...
Страница 64: ...2 10 General Description Rear View ...
Страница 68: ...2 14 General Description CPU IO Module CPU IO module ...
Страница 88: ...2 34 General Description This page is intentionally left blank ...
Страница 100: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled ...
Страница 101: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner ...
Страница 218: ...4 92 System Configuration This page is intentionally left blank ...
Страница 253: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed ...
Страница 390: ...5 172 Installing and Using Utilities This page is intentionally left blank ...
Страница 408: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1 ...
Страница 410: ...6 20 Maintenance This page is intentionally left blank ...
Страница 454: ...7 44 Troubleshooting This page is intentionally left blank ...
Страница 485: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035 ...
Страница 500: ......
Страница 503: ......