System Configuration 4-71
LAN
(1)
The MAC address of the BMC
(2)
Allows you to choose whether or not to acquire an IP address automatically by DHCP.
(3)
Allows you make the IP address settings if the address is not acquired automatically by
DHCP. If the address is acquired automatically by DHCP, the data acquired is shown here.
IMPORTANT:
Specify different IP addresses to CPU/IO module #0 and CPU/IO module #1.
If you change the IP address, the current connection will be disconnected when the BMC
settings are completed by clicking OK. Close the window once, and then log on again by
entering the newly set IP address (or host name) in the browser.
The logon page remaining on the browser is the page you accessed by using the old address.
You cannot use it to log on.
When you configure “default gateway,” the gateway, the server, the management PC should
be in a state where communication over network is available.
If you make the settings in a state where communication is not available, you need to switch
on/off the AC of the server in a state where the gateway, the server and the management PC
can be communicated over the network.
After you changed the DHCP setting, you should turn off the AC power of the system and
turn on it after 5 seconds or more.
After you changed the DHCP setting using NEC EXPRESSBUILDER and NEC DianaScope
Agent, you should turn off the AC power of the system and turn on it after 5 seconds or
more..
1
2
3
Содержание EXP320J
Страница 12: ... THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 25: ...xiii APPENDIX A SPECIFICATIONS A 1 APPENDIX B I O PORT ADDRESSES B 1 ...
Страница 26: ...xiv THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 28: ...1 2 Precautions for Use 使用上的注意 本章包含著對服務器恰當安全的操作必要的信息 ...
Страница 54: ...1 28 Precautions for Use This page is intentionally left blank ...
Страница 64: ...2 10 General Description Rear View ...
Страница 68: ...2 14 General Description CPU IO Module CPU IO module ...
Страница 88: ...2 34 General Description This page is intentionally left blank ...
Страница 100: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled ...
Страница 101: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner ...
Страница 218: ...4 92 System Configuration This page is intentionally left blank ...
Страница 253: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed ...
Страница 390: ...5 172 Installing and Using Utilities This page is intentionally left blank ...
Страница 408: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1 ...
Страница 410: ...6 20 Maintenance This page is intentionally left blank ...
Страница 454: ...7 44 Troubleshooting This page is intentionally left blank ...
Страница 485: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035 ...
Страница 500: ......
Страница 503: ......