Installation Restrictions
•
Before installing the terminal, read and follow the guidelines in the
NCR EasyPoint 7401 Site Preparation Guide and the NCR
Workstation and Peripheral AC Wiring Guide.
•
Install the terminal near an electrical outlet that is easily accessible.
Use the power cord as a power-disconnect device.
•
Do not permit any object to rest on the power cord. Do not locate
the terminal where the power cord can be walked on.
•
Use a grounding strap or touch a grounded metal object to
discharge any static electricity from your body before servicing the
terminal.
•
If the power cord is replaced, it must be replaced with the same
type of cord with the protective shroud.
•
Do not route the power cord through openings with sharp edges.
Caution:
This unit contains hazardous voltages and should only be
serviced by qualified service personnel.
Caution:
DO NOT connect or disconnect the transaction printer while
the terminal is connected to AC power. This can result in system or
printer damage.
Warning:
The 7401 must be mounted securely to prevent a hazard. It
must be installed in accordance with local building codes. The post
or wall on which the unit is mounted should be able to withstand
four times the weight of the unit, which is approximately 20 lbs.
(9 kg).
Содержание EasyPoint 7401
Страница 1: ...NCR EasyPoint 7401 Release 2 5 Hardware User s Guide 19797 NCR B005 0000 1254 Issue H...
Страница 18: ...xvi...
Страница 24: ...xxii...
Страница 98: ......
Страница 117: ...Chapter 3 7401 2xxx and 3xxx Hardware Installation 3 19 2 Remove the Core Module from the Fixed Angle Mount 16397...
Страница 156: ......
Страница 188: ...4 32 Chapter 4 7401 4xxx Hardware Installation...
Страница 220: ...5 32 Chapter 5 Setup...
Страница 260: ...7 10 Chapter 7 BIOS Updating Procedures...
Страница 266: ...8 6 Chapter 8 NCR 7401 7890 or 7892 Scanner Differences...
Страница 279: ......
Страница 280: ...B005 0000 1254 Dec 2002 Printed on recycled paper...