Data packet is recoreded
It occurs at the moment of recording the data packet for
transmission from any source.
Logic
Active
Inactive
Shock sensor
It occurs at when the "the accelerometer sensitivity" value is
exceeded of in the track settings for transmission via GPRS /
WiFi communication channels
Logic
Active
Inactive
Longitudinal tilt
It occurs at when the "the maximum value of the longitudinal
tilt" specified in the "Inertial Monitoring" settings is exceeded
Logic
Active
Inactive
Lateral tilt
It occurs when the "the maximum value of the lateral tilt"
specified in the "Inertial Monitoring" settings is exceeded
Logic
Active
Inactive
Speed in the geofence on the route
The speed value when going in geofences of the selected
route. Beyond geofences the value is zero.
Целочисленное
Output from the dynamic geo-fence
It occurs at a time of leaving the dynamic geo-fence at the
same time creating a new one.
Logic
Active
Inactive
Third-party key
It occurs if the iButton key is recorded in the memory of the
device or removable storage (sdCard)
Logic
Active
Inactive
Battery operation
It occurs if at the time of the transition to work powered by
built-in battery in the absence of external power.
Logic
Active
Inactive
Program timer 1-5
It occurs:
1. When the timer value corresponds to the comparison
function selected for it.
2. While comparing of the state of running (active)/stopped
(not active)
Logic
Active
Inactive
More
Less
Equal
Not equal
More or equal
Less or equal
Program counter 1-12
It occurs when the counter value corresponds to the
comparison function selected for it
Integer-valued
More
Less
Equal
Not equal
More or equal
Less or equal
Program flag 1-12
It occurs at the moment of check of the flag state if the
comparison function has the propper value
Active
Inactive
Main actions (response to an active event):
Parameter
Description
Taken values
Operation
Start events processing
Perform the actions of any of the created events even if the
conditions for this event are not fulfilled. ATTENTION! It may
lead to an infinite cycle.
Number one of the existing
events. For the current one the
specified number is 256.
-
Send an extraordinary packet
Record to buffer for transmission of extraordinary data packet
-
-
Play a voice phrase
Plays a voice phrase
The full file name is entered
manually
-
Play an audio file
Plays the audio file with the specified name. The file must be
located on the SD card in the directory .. \voice\
The full file name is entered
manually
Wait until the call is answered
It works in a group with the action "Dial XXX" or "Dial number
from the list"
For the convenience of the user, after creating an event, you can go to the emulation mode. In this
mode, next each condition its current state is specified. When the action is performed, the action being
performed is specified.
8. CONFIGURATION WIZARD
The configurator allows you to set the most common configuration used for this wizard in automatic
mode. After you have completed the settings, the connection diagram for specifically-set configuration is
displayed.
To make settings you should go from point to point by entering the required parameters:
1.
Select the connection parameters - IP address and port of the server, choose the GPRS
connection provider and the unique device IDD.
2.
To go to the next menu press the "Next" button
3.
2. Selection of the connected peripherals. The setup wizard can automatically configure the
following connected peripherals:
4.
- FUEL GAUGE - It can be analog, frequency or digital sensor. The necessary interface is installed
(See Table 4). After selecting the sensor type, choose an input for analog sensors or a port for
digital ones and network address. If the sensor is configured and connected properly, in the
current value field a number different from zero will be displayed. After completing the setup
wizard, the sensor can be calibrated by the calibration wizard.